The LSLV-H100 sets the standard for the drive industry. Environmentallyfriendly water treatment and Fan and Pump systems incorporate the outstanding energy-saving benefits of the LSLV-H100 for fans and pumps. LSLV-H100 drives include a user-friendly keypad designed exclusively for the Fan and Pump market and satisfy various needs of customers.
Additional links: Technical documentation and DownloadsRequest additional information and get a price quote |
Model range
H100 pump and fan series (3 phase 200-240 V)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
LSLV0008H100-2CONN | 0.75 | 5 | 0-600 | - | reduced! | |
LSLV0015H100-2CONN | 1.5 | 8 | 0-600 | - | reduced! | |
LSLV0022H100-2CONN | 2.2 | 12 | 0-600 | - | reduced! | |
LSLV0037H100-2CONN | 3.7 | 16 | 0-600 | - | reduced! | |
LSLV0055H100-2CONN | 5.5 | 22 | 0-600 | - | reduced! | |
LSLV0075H100-2CONN | 7.5 | 30 | 0-600 | 160x232x181 | 669,00 € | |
LSLV0110H100-2CONN | 11 | 42 | 0-600 | 160x232x181 | 679,00 € | |
LSLV0150H100-2CONN | 15 | 56 | 0-600 | 180x290x205,3 | 792,00 € | |
LSLV0185H100-2CONN | 18.5 | 69 | 0-600 | 220x350x223,2 | 1 017,00 € |
H100 pump and fan series (3 phase 380-480 V)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
LSLV0008H100-4COFN | 0.75 | 2.5 | 0-600 | - | reduced! | |
LSLV0015H100-4COFN | 1.5 | 4 | 0-600 | - | reduced! | |
LSLV0022H100-4COFN | 2.2 | 6 | 0-600 | - | reduced! | |
LSLV0037H100-4COFN | 3.7 | 8 | 0-600 | - | reduced! | |
LSLV0055H100-4COFN | 5.5 | 12 | 0-600 | - | reduced! | |
LSLV0075H100-4COFN | 7.5 | 16 | 0-600 | 160x232x181 | 665,00 € | |
LSLV0110H100-4COFN | 11 | 24 | 0-600 | 160x232x181 | 693,00 € | |
LSLV0150H100-4COFN | 15 | 30 | 0-600 | 180x290x205,3 | 1 017,00 € | |
LSLV0185H100-4COFN | 18.5 | 38 | 0-600 | 180x290x205,3 | 1 048,00 € | |
LSLV0220H100-4COFN | 22 | 45 | 0-600 | 220x350x223,2 | 1 227,00 € | |
LSLV0300H100-4COFN | 30 | 61 | 0-600 | 220x350x223,2 | 1 403,00 € | |
LSLV0370H100-4COFD | 37 | 75 | 0-600 | 275x450x284 | 2 108,00 € | |
LSLV0450H100-4COFD | 45 | 91 | 0-600 | 325x510x284 | 2 536,00 € | |
LSLV0550H100-4COFD | 55 | 107 | 0-600 | 325x510x284 | 2 961,00 € | |
LSLV0750H100-4COND | 75 | 142 | 0-600 | 325x550x309 | 3 071,00 € | |
LSLV0900H100-4COND | 90 | 169 | 0-600 | 325x550x309 | 3 646,00 € |
Maximized User Convenience with LS frequency inverter H100 series
LSLV-H100 drives include a user-friendly keypad designed exclusively for the HVAC market and satisfy various needs of customers.
Keypad Exclusive for HVAC
Used to issue commands, configure drive parameters, and for monitoring drive status.
-HAND Mode (Local Control Mode) or AUTO Mode (Remote Control Mode) can be selected: HAND Mode: Used when selecting frequency or run/stop commands, AUTO Mode: Drive operated using the keypad, multifunctional terminal block and communications.
- Fault Status Monitoring
Built-in EMC filter
A built-in EMC filter to respond to the specifications for noise reduction
- 400V 0.75~30kW Built-in as default (C3)
- 400V 37~55kW Built-in option can be selected (C3)
Communication Module
- RS-485 capability is built-in
- BACnet MS/TP is embedded as standard
- Modbus-RTU, Metasys N2
- LonWorks option can be added
Easy to Change Cooling Fan
It is easy to change a cooling fan without opening the cover of a drive.
DC Reactor
A built-in DC Reactor effective to improve power factor and reduce THD is installed.
- DC Reactor built-in as standard for 400V 37~90kW
Specification Level Option (Conduit Kit)
Acquired UL open type & enclosed type 1 certification.
- When the conduit option is used, the drive meets UL Enclosed Type 1 specifications
Software Exclusive for LS Drives
DriveView7 can be connected using USB Port or RJ45 terminal.
LS vfd H100 series has Stable System Control
LSVL-H100 drives are intelligent drives equipped with various protective and operation functions for continuously stable operation in response to external environmental changes.
Soft Fill Operation
Prevents pump damages caused by dramatic pressure changes during initial operation of pumps or inside pumps.
Start Ramp & End Ramp
Prevents pump damage by changing ramp using acceleration/ deceleration time setting upon initial pump operation and stop.
Dec Valve Ramp
Prevents pump and pipe damages caused by sudden pressure changes when pumps are stopped or a pump valve is closed, deceleration time can be set.