M100 low voltage micro drive with built-in EMC filter and DB unit is built to save money and time.
Additional links: Technical documentation and DownloadsRequest additional information and get a price quote |
Model range
M100 (1 phase 200-240 V)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
LSLV0001M100-1EOFNA | 0.1 | 0.8 | 0-6000 | 85x145x100 | 125,00 € | |
LSLV0002M100-1EOFNA | 0.2 | 1.4 | 0-6000 | 85x145x100 | 135,00 € | |
LSLV0004M100-1EOFNA | 0.4 | 2.4 | 0-6000 | 85x163x123 | 142,00 € | |
LSLV0008M100-1EOFNA | 0.75 | 4.2 | 0-6000 | 85x163x123 | 153,00 € | |
LSLV0015M100-1EOFNA | 1.5 | 7.5 | 0-6000 | 100x190x140 | 191,00 € | |
LSLV0022M100-1EOFNA | 2.2 | 10 | 0-6000 | 100x190x140 | 211,00 € |
Verify & Identify the LS frequency inverter M100 series
- Inspect the drive for damage. If the drive appears damaged upon receipt, contact your supplier.
- Verify receipt of the correct model by checking the information on the nameplate as shown below. If you have received the wrong model, contact your supplier.
Mount the LS drive M100 series
- Ensure that there is sufficient space to meet the clearance specifications, and that there are no obstacles impeding the cooling fan’s air flow as shown below.
- When installing multiple drives into the same enclosure panel (Side-by-side installation), mount the drives with the minimum clearance of 2 mm while removing optional top covers.
- Install the drive in an environment that meet the conditions such as ambient temperature (-10℃ to 50℃), Humanity (95% relative humidity or free of condensation), altitude (below 1,000m) and vibration (below 1G [9.8 m/sec2])
- DIN-Rail mounting is available