Compact inverters VF-FS1 series inverter designed to control heating, air conditioning and ventilation systems, used in exhaust fans, boilers, waste water systems, cold and hot water heating, thermal power plants, power plants, etc.
Additional links: Technical documentation and DownloadsRequest additional information and get a price quote |
Model range
VF-FS1 fan and pump series (3 phase 200-240 V)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
VFFS1-2004PM | 0.4 | 2.8 | 0,1-3200 | 107х130х150 | reduced! | |
VFFS1-2007PM | 0.75 | 4.6 | 0,1-3200 | 107х130х150 | reduced! | |
VFFS1-2015PM | 1.5 | 7.5 | 0,1-3200 | 107х130х150 | reduced! | |
VFFS1-2022PM | 2.2 | 10.6 | 0,1-3200 | 107х130х150 | reduced! | |
VFFS1-2037PM | 4 | 17.5 | 0,1-3200 | 142х170х150 | reduced! | |
VFFS1-2055PM | 5.5 | 24.2 | 0,1-3200 | 180х220х170 | reduced! | |
VFFS1-2075PM | 7.5 | 32 | 0,1-3200 | 180х220х170 | reduced! | |
VFFS1-2110PM | 11 | 46.2 | 0,1-3200 | 245х310х190 | reduced! | |
VFFS1-2150PM | 15 | 61 | 0,1-3200 | 245х310х190 | reduced! | |
VFFS1-2185PM | 18,5 | 74.8 | 0,1-3200 | 245х310х190 | reduced! | |
VFFS1-2220PM | 22 | 88 | 0,1-3200 | 240х420х214 | reduced! | |
VFFS1-2300PM | 30 | 117 | 0,1-3200 | 320х630х290 | reduced! |
VF-FS1 fan and pump series (3 phase 380-480 V)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
VFFS1-4004PL | 0.4 | 1.4 | 0,1-3200 | 107х130х150 | reduced! | |
VFFS1-4007PL | 0.75 | 2.2 | 0,1-3200 | 107х130х150 | reduced! | |
VFFS1-4015PL | 1.5 | 3.7 | 0,1-3200 | 107х130х150 | reduced! | |
VFFS1-4022PL | 2.2 | 5.1 | 0,1-3200 | 107х130х150 | reduced! | |
VFFS1-4037PL | 4 | 9.1 | 0,1-3200 | 142х170х150 | reduced! | |
VFFS1-4055PL | 5.5 | 12 | 0,1-3200 | 180х220х170 | reduced! | |
VFFS1-4075PL | 7.5 | 16 | 0,1-3200 | 180х220х170 | reduced! | |
VFFS1-4110PL | 11 | 22.5 | 0,1-3200 | 180х220х170 | reduced! | |
VFFS1-4150PL | 15 | 30.5 | 0,1-3200 | 245х310х190 | reduced! | |
VFFS1-4185PL | 18.5 | 37 | 0,1-3200 | 245х310х190 | reduced! | |
VFFS1-4220PL | 22 | 43.5 | 0,1-3200 | 240х420х214 | reduced! | |
VFFS1-4300PL | 30 | 58.5 | 0,1-3200 | 240х420х214 | reduced! | |
VFFS1-4370PL | 37 | 79 | 0,1-3200 | 240х550х214 | reduced! | |
VFFS1-4450PL | 45 | 94 | 0,1-3200 | 240х550х214 | reduced! | |
VFFS1-4550PL | 55 | 116 | 0,1-3200 | 320х630х290 | reduced! | |
VFFS1-4750PL | 75 | 160 | 0,1-3200 | 320х630х290 | reduced! |
Toshiba frequency inverter VF-FS1 series - half installation space and less wiring.
Reactor-less harmonic suppress technologies and builtin filter reduce 50% of installation space, save time and cost of wiring. And side-by-side installation realizes effective utilization of space in control panels.
Toshiba drive VF-FS1 series has reactor-less harmonics reduction and high-frequency noise reduction.
Harmonics reduction, Power factor improvement.
Toshiba unique technologies suppress harmonics, particularly 5th and 7th harmonic current that affect power sources. And the power factor in all models has been improved. Harmonics are controlled to within the Total Harmonic Distortion (THD) of international standard IEC61000-3-12 without any external reactor. ( Rsce >=120 ).
High-frequency noise reduction.
High-frequency noise is drastically reduced on models with built-in noise filters. Built-in noise filters are ideal for office, commercial facilities, and factories where special attention for peripheral devices are needed. Compared with existing model, less space and wiring are realized by incorporating filter in the panel. In addition, models with built-in EMC noise filter comply with the European EMC Directive as individual inverter units.
Long life and easy maintenance.
- 15 years life designed main capacitors
- An alarm warns when the main circuit capacitors, circuit boards capacitors, or cooling fan needs to be replaced.
- Cooling fan’s On/Off control extend its life
- Easy replacement of cooling fan by one touch
- The inverter unit can be replaced by removable terminal block without disconnecting cables.
Special softwares for fan and pump application are built-in in Toshiba frequency inverter VF-FS1 series.
- The local or remote operation can be selected by one touch.
- Bumpless function realize seamless operation between local and remote.
- Fire control enables forced operation in emergency. In case of emergency, forced control will run by specified frequency. The forced operation signal will be saved when the signal turns ON. Motor does not stop in the event of the occurrence of a soft fault.
- Speed reference can manage on/off operation. (sleep function)
- Low current detection can notice a broken belt or low load for pump application
- PTC thermistor input
- Built-in RS485 (TOSHIBA/Modbus protocol) communication as standard. Optional fieldbuses for LONWORKS®, BACnet®, Metasys®N2 and APOGEE® FLN as built in option.
More energy saving and easier operation with Toshiba drive VF-FS1 series.
More energy saving.
The advanced energy-saving mode optimizes fan and pump efficiency even at normally inefficient in low speeds. The effect can be monitored by operation panel or through serial communication data.
Easy operation.
A wizard function enable set the 10 most often used parameter quickly. It can be sequentially, such as installing the PC software.
Macro function for basic parameters by one setting is available as shown below:
- The coast stop
- The 3-wire operation
- External input UP/DOWN setting
- 4 to 20mA current input operation
The startup or adjustments are supported by the history function that displays the latest 5 changed parameters.
Toshiba vfd VF-FS1 series communications software and options.
Communications software.
The PCM001Z communications software allows you to edit, monitor, and trace parameter data on a PC. It realize easier data management for commissioning and maintenance.
Options.
USB communications conversion unit.
This is a unit which converts USB port signal to VF inverter serial port for data communication. Optional cables to USB and inverter unit are required. By using serial data communication, all parameters and monitoring data can be accessed for commissioning and maintenance.
Network.
Built-in HVAC fieldbuses option are available to communicate with a host controller for centralized control.
- LONWORKS®
- BACnet®
- Metasys® N2
- APOGEE® FLN
LED extension panel.
The panel with 20 mm height LEDs displays frequency and parameters very clearly at sight. In addition, it can save and download up to three sets of individual parameters as a parameter writer.
External EMC directive compliant noise reduction filter.
It can be complied to the following directives by installing this filter
- 400V class:IEC/EN61800-3,1st Environment,C1 or IEC/EN61800-3, 1st Environment,C2
- 200V class:IEC/EN61800-3,1st Environment,C2 or IEC/EN61800-3,2nd Environment,C3