Toshiba frequency inverter VF-nC3 general purpose series

Toshiba
 

VF-nC3 fequency inverter series allow the implementation of various technological tasks depending on the application and customer requirements.


  • The output frequency range from 0.5 Hz to 400
  • Accuracy of output frequency up to 0.5%
  • Overcurrent 150% - 60 secs
  • Operating Temperature -10 ... + 60 ° C
  • Start feature enhancement point avtopodhvat rotating motor, a regenerative mode when the momentary supply voltage, 2 sets of acceleration and deceleration times
  • Volt frequency motor control (constant and variable torque mode), sensorless vector control engine speed with auto-tuning of motor parameters, tuning lifting motor torque at low speed, automatic torque boost
  • Reference frequency integrated dialer wheel or external potentiometer with built-in or external control panel, selecting one of 15 preset speeds, analog signal
  • PID controller with control sensor failure
  • Built-in EMC filter
  • Built-in RS-485 port (ModBus RTU support)

Additional links:

 Technical documentation and Downloads
 Request additional information and get a price quote
 

Model range

VF-nC3 general purpose series (1 phase 100-120 V)

Model Capacity,
kW
Current,
A
Deceleration time, sec Dimensions
(W x H x D), mm
Price
VFNC3S-1001P 0.1 0.7 0-3000 72х130х102 reduced!
VFNC3S-1002P 0.2 1.4 0-3000 72х130х102 reduced!
VFNC3S-1004P 0.4 2.4 0-3000 72х130х121 269,00 €
VFNC3S-1007P 0.75 4.2 0-3000 105х130х156 357,00 €

VF-nC3 general purpose series (1 phase 200-240 V)

Model Capacity,
kW
Current,
A
Deceleration time, sec Dimensions
(W x H x D), mm
Price
VFNC3S-2001PL 0.1 0.7 0-3000 72х130х102 reduced!
VFNC3S-2002PL 0.2 1.4 0-3000 72х130х102 191,00 €
VFNC3S-2004PL 0.4 2.4 0-3000 72х130х121 217,00 €
VFNC3S-2007PL 0.75 4.2 0-3000 72х130х131 224,00 €
VFNC3S-2015PL 1.5 7.5 0-3000 105х130х156 293,00 €
VFNC3S-2022PL 2.2 10 0-3000 105х130х156 329,00 €

VF-nC3 general purpose series (3 phase 200-240 V)

Model Capacity,
kW
Current,
A
Deceleration time, sec Dimensions
(W x H x D), mm
Price
VFNC3S-2001P 0.1 0.7 0-3000 72х130х102 reduced!
VFNC3S-2004P 0.2 1.4 0-3000 72х130х102 reduced!
VFNC3S-2005P 0.4 2.4 0-3000 72х130х121 reduced!
VFNC3S-2007P 0.75 4.2 0-3000 72х130х131 reduced!
VFNC3S-2037P 4 16.7 0-3000 140х170х141 reduced!

Toshiba frequency inverter VF-nC3 series is easy to operate.

The “turn-and-push” setting dial makes setup easy.
The large setting dial at the center of the front panel allows you to set the parameters easily. Just turn the setting dial until you get the right parameter and push the setting dial to select. You can also use the setting dial to set the reference frequency.
The RUN and STOP keys allow to operate easily.
You can operate the inverter with the RUN and STOP keys on the front panel. The front cover may be closed to conceal the other keys to avoid accidental key presses.
Toshiba frequency inverter VF-nC3 series is easy to operate.

Toshiba drive VF-nC3 series is easy to set up.

Easy to set parameters. 
In Easy mode, you can navigate through only the most commonly used parameters. The EASY key allows you to switch between Easy mode and Standard mode.
- Easy mode : Scrolls through a list of only eight parameters. You can optionally add up to 24 parameters to the list.
- Standard mode : Rotates through all parameters.
Guides you step by step through parameters you need to set up.
- Since the guidance feature shows one parameter at a time according to the selected function, you can interactively edit its value. Auto-guidance function is available with motor parameter setup, preset speed selection, analog signal control and etc

Built-in RS-485 communication.
Built-in RS-485 communication enable to control the inverter and construct the inverter and construct the network. 
- Communication rate maximum 38.4 kbps
- Compatible with the Modbus RTU and Toshiba protocols.
You can connect a PC to manage parameters and monitor operating conditions.
Toshiba drive VF-nC3 series is easy to set up.

Toshiba vfd VF-nC3 series is easy to install.

The vertically oriented main circuit terminal block allows easy wiring.
- Like power distribution devices, the main circuit terminal block of the VF-nC3 is vertically oriented to make wiring easy and minimize tangles of cable.
Side-by-side installation for space-saving.
- Generally, inverters must be placed, taking heat dissipation into consideration. The VF-nC3 can be placed side by side with no gap, saving inside of control panel space.*
The covers for the main circuit terminal block ensure safety.
- You can remove the covers for the main circuit terminal block with a screwdriver. Since the covers can be attached after the wiring of the main circuit terminal block, the VF-nC3 can be installed easily and safely.
Toshiba vfd VF-nC3 series is easy to install.
Wide Operating Conditions and Compliance with Global Standards.
- Maximum ambient temperature: 60°C*
- Maximum altitude: 3000 meters*
- Support for single-phase power supply : Supports three-phase 240V, single-phase 240V and single-phase 120V power supplies. Note : For single-phase 240V and 120V inputs, the VF-nC3 provides a three-phase 200V output.
- Compliant with global standards.

All either copying or distribution of any material or information from asb-drives.eu website of Advanced Systems Baltic OÜ is forbidden unless it is allowed exclusively upon written authorization by the possessor of rights.
Bonfiglioli Inverters (VFD)
Fuji Electric Inverters (VFD)
Hitachi Inverters (VFD)
LS Inverters (VFD)
Mitsubishi Inverters (VFD)
ABB ACS580
ABB ACS880