Delta's CFP2000 series is an AC motor drive specially designed for HVAC, fans & pumps, and water treatment applications. It is designed with an IP55 enclosure to provide effective protection from dust and other particles and to offer a good level of protection from water. In addition, it includes many outstanding features and built-in functions that reduce setup and tuning time in operation and provide higher efficiency. The CFP2000 is equipped with a built-in EMC filter and a DC choke. This design replaces the need for an electrical distribution cabinet and saves space for other devices, while providing the benefits of harmonic suppression and better power quality to the system. Various parameter groups are also included, which allow you to simply select the needed application in the parameter group setting and the system setup is ready. If a higher safety standard is required, an optional main switch function is also available upon selection. Other outstanding features include support for both IM/PM motors, a real time clock, built-in 10k steps PLC capacity and various optional extension cards. The CFP2000 series integrates all of your needs into one drive. It is the friendliest and smartest choice available in the industry. Applications: HVAC, fans, pumps, cooling systems, factory water supply & water treatment systems.
Additional links: Technical documentation and DownloadsRequest additional information and get a price quote |
Model range
CFP2000 (3 phase 380 V)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
VFD007FP4EA | 0.75 | 3 | 0-600/0-6000 | 161x366,4x244 | 835,00 € | |
VFD015FP4EA | 1.5 | 4.2 | 0-600/0-6000 | 161x366,4x244 | 871,00 € | |
VFD022FP4EA | 2.2 | 5.5 | 0-600/0-6000 | 161x366,4x244 | 928,00 € | |
VFD037FP4EA | 3.7 | 8.5 | 0-600/0-6000 | 161x366,4x244 | 947,00 € | |
VFD040FP4EA | 4 | 10.5 | 0-600/0-6000 | 161x366,4x244 | 966,00 € | |
VFD055FP4EA | 5.5 | 13 | 0-600/0-6000 | 161x366,4x244 | 985,00 € | |
VFD075FP4EA | 7.5 | 18 | 0-600/0-6000 | 161x366,4x244 | 1 003,00 € | |
VFD110FP4EA | 11 | 24 | 0-600/0-6000 | 216x491,4x274 | 1 308,00 € | |
VFD150FP4EA | 15 | 32 | 0-600/0-6000 | 216x491,4x274 | 1 451,00 € | |
VFD185FP4EA | 18,5 | 38 | 0-600/0-6000 | 216x491,4x274 | 1 873,00 € | |
VFD220FP4EA | 22 | 45 | 0-600/0-6000 | 216x491,4x274 | 2 243,00 € | |
VFD300FP4EA | 30 | 60 | 0-600/0-6000 | 282x630x310 | 3 000,00 € | |
VFD370FP4EA | 37 | 73 | 0-600/0-6000 | 282x630x310 | 3 434,00 € | |
VFD450FP4EA | 45 | 91 | 0-600/0-6000 | 308x680x352 | 4 051,00 € | |
VFD550FP4EA | 55 | 110 | 0-600/0-6000 | 308x680x352 | 4 891,00 € | |
VFD750FP4EA | 75 | 150 | 0-600/0-6000 | 370xx770x380 | 5 713,00 € | |
VFD900FP4EA | 90 | 180 | 0-600/0-6000 | 370xx770x380 | 6 280,00 € |
Delta CFP2000 Fan and Pump Series Features
Motor controls- IM motor
- PM motor
I/O terminals
• 10 MI • 2 AO
• 3 AI • 3 relay
• Optional I/O extension cards
Overload ability
Light duty:
120% for 60sec
Normal duty:
120% for 60sec
160% for 3sec
Built-in STO SIL2
Mains Switch (Optional)
• Available for all IP55 models 0.75kW to 90kW
• Allows users to turn off the power easily during daily maintenance and does not require an additional breaker box
Built-in PLC Function
• Built-in 10k steps PLC function supports independent and distributed control when connecting to a network system for high operation flexibility.
• Real Time Clock (RTC) function facilitates the PLC program writing process for ON/OFF chronology, daylight savings operation and many other settings.
Skip Frequency
• Skip Frequency function avoids motor vibration at a specific frequency band and protects the equipment. User can restrict up to 3 zones of frequency range
Fire Mode
• Application: ventilation of buildings, tunnels, subways and more
• The drive will bypass the alarm warning in fire mode. When a fire occurs, it forces the drive to continue to operate to extract smoke or supplies water until the drive fails or runs out of emergency power
» Preset speed mode: set the drive to continue to operate under a preset speed
» BYPASS mode: the AC Mains Bypass breaker will bypass the drive and connect to the emergency power
» Fire mode with PID control: it balances the pressure between the stairwell and fire location to ensure the fire door can be easily opened
Flying Start
• Ensures the drive runs smoothly under high inertial load without triggering the alarm, does not require the motor to stop
• When the drive restarts after momentary power loss (within 5s on LV), the speed searching allows the drive to activate flying start immediately and ensure a stable operation of the system without requiring the motor to fully stop in order to save time
Multi-pumps control
• Fixed time circulation (by time)
• Fixed amount circulation (by PID)
• Fixed amount control (by PID)
• Fixed time circulation + fixed amount circulation
• Fixed time circulation + fixed amount control
Built-in 10k steps PLC function and RTC for user to program a time sequence control
Parameter groups
Advanced network functions
• Built-in RS-485 (MODBUS)
• Built-in BACnet MS/TP
• Various communication card options
DeviceNet, MODBUS TCP, CANopen (DS402), Ethernet/IP, ProfiBus
Delta CFP2000 Operating Environment
Download manuals (all parameters)