Invertek Drives frequency inverter Optidrive Eco HVAC series

Invertek Drives
 

Optidrive Eco HVAC provides a perfect solution to the needs of designers looking to optimise the performance of fans and pumps used in HVAC applications, allowing them to operate with maximum efficiency under all conditions. Invertek Drives’ philosophy to provide innovative products with easy to use, energy efficient features ensures that time, cost and energy savings are maximised at all times, resulting in the shortest possible payback period – the time taken to recover the initial product and installation costs through financial savings achieved through installing Optidrive Eco HVAC drives. For simple installation into your buildings management system all Optidrive Eco HVAC drives are provided with both BACnet and Modbus RTU as standard across the product range.


  • Eco Vector Motor Control
  • Energy Optimised Design
  • Internal EMC filter
  • Low noise operation
  • Accurate speed control
  • Sleep & wake functions
  • Intelligent maintenance interval
  • Automatic load monitoring
  • Built in keypad and OLED text display
  • Practical design
  • Integrated PID controller

Additional links:

 Technical documentation and Downloads
 Request additional information and get a price quote
 

Model range

Optidrive Eco HVAC series (1 phase 200-240 V)

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
ODV-3-220043-1F12-MN 0.75 4.3 110x221x185 reduced!
ODV-3-220070-1F12-MN 1.5 7 110x221x185 reduced!
ODV-3-220105-1F12-MN 2.2 10.5 110x221x185 reduced!

Optidrive Eco HVAC series (3 phase 200-240 V)

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
ODV-3-220043-3F12-MN 0.75 4.3 110x221x185 reduced!
ODV-3-220070-3F12-MN 1.5 7 110x221x185 reduced!
ODV-3-220105-1F12-MN 2.2 10.5 110x221x185 reduced!
ODV-3-320180-3F12-MN 4 18 131x261x205 reduced!
ODV-3-320240-3F12-MN 5.5 24 131x261x205 reduced!
ODV-3-420300-3F12-MN 7.5 30 131x261x205 reduced!
ODV-3-420460-3F12-MN 11 46 160x418x240 reduced!
ODV-3-520610-3F12-MN 15 61 222x486x260 reduced!
ODV-3-520720-3F12-MN 18.5 72 222x486x260 reduced!
ODV-3-520900-3F12-MN 22 90 222x486x260 reduced!
ODV-3-621100-3F12-MN 30 110 286x614x320 reduced!
ODV-3-621500-3F12-MN 37 150 286x614x320 reduced!
ODV-3-621800-3F12-MN 45 180 286x614x320 reduced!
ODV-3-722020-3F1N-TN 55 202 330x1280x360 reduced!
ODV-3-722400-3F1N-TN 75 248 330x1280x360 reduced!

Optidrive Eco HVAC series (3 phase 380-480 V)

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
ODV-3-240022-3F12-MN 0.75 2.2 110x221x185 reduced!
ODV-3-240041-3F12-MN 1.5 4.1 110x221x185 reduced!
ODV-3-240058-3F12-MN 2.2 5.8 110x221x185 reduced!
ODV-3-240095-3F12-MN 4 9.5 110x221x185 reduced!
ODV-3-340140-3F12-MN 5.5 14 131x261x205 reduced!
ODV-3-340180-3F12-MN 7.5 18 131x261x205 reduced!
ODV-3-340240-3F12-MN 11 24 131x261x205 reduced!
ODV-3-440300-3F12-MN 15 30 160x418x240 reduced!
ODV-3-440390-3F12-MN 18.5 39 160x418x240 reduced!
ODV-3-440460-3F12-MN 22 46 160x418x240 reduced!
ODV-3-540610-3F12-MN 30 61 222x486x260 reduced!
ODV-3-540720-3F12-MN 37 72 222x486x260 reduced!
ODV-3-540900-3F12-MN 45 90 222x486x260 reduced!
ODV-3-641100-3F12-MN 55 110 286x614x320 reduced!
ODV-3-641500-3F12-MN 75 150 286x614x320 reduced!
ODV-3-641800-3F12-MN 90 180 330x726x320 reduced!
ODV-3-642020-3F12-MN 110 202 330x726x320 reduced!
ODV-3-742400-3F1N-TN 132 240 330x1280x360 reduced!
ODV-3-743020-3F1N-TN 160 302 330x1280x360 reduced!
ODV-3-843700-3F12-MN 200 370 482x995x480 reduced!
ODV-3-844500-3F12-MN 250 450 482x995x480 reduced!

Invertek Drives Optidrive Eco HVAC - energy efficient fan and pump control

Modern building ventilation and air conditioning systems are designed to provide optimum climatic conditions for occupants throughout the whole year. As such, they must be designed to operate equally well during the hottest part of the day, with maximum sunlight, through to the colder night time and winter periods. Building designers must take account of these extremes and select components and systems capable of providing the required level of occupant comfort under all conditions. This results in systems operating the majority of the time at less than maximum capacity, which can mean reduced efficiency and wasted energy.

Optidrive Eco HVAC provides a perfect solution to the needs of designers looking to optimise the performance of fans and pumps used in HVAC applications, allowing them to operate with maximum efficiency under all conditions. Invertek Drives’ philosophy to provide innovative products with easy to use, energy efficient features ensures that time, cost and energy savings are maximised at all times, resulting in the shortest possible payback period – the time taken to recover the initial product and installation costs through financial savings achieved through installing Optidrive Eco HVAC drives.

For simple installation into your buildings management system all Optidrive Eco HVAC drives are provided with both BACnet and Modbus RTU as standard across the product range.

From the data, it can be clearly seen that using methods such as dampers to restrict the airflow is much less efficient than controlling the speed of the fan using an Optidrive Eco HVAC.



Save energy
- Accurate speed control of fans and pumps provides the most energy efficient control method
- Energy optimisation function minimises energy usage in real time under partial load conditions
- Sleep & wake functions ensure operation only when required

Save money
- Advanced on-board features remove the need for peripheral equipment
- Intelligent maintenance interval timing allows programmable maintenance reminders, avoiding costly downtime
- Automatic load monitoring provides an early warning of potential faults, such as belt failures or blocked filters

Save time
- Built in keypad and OLED text display provides intuitive operation
- Simple parameter structure with carefully selected default values reduce commissioning time
- Practical design allows easy access to power and control terminals without specialist tools

Optidrive Eco HVAC key features
- ECO Vector Motor Control
- Standard Induction Motors
* Permanent Magnet AC Motors
* Brushless DC Motors
* Synchronous Reluctance Motors
- Energy Optimised Design
- Internal EMC Filter
- Low Noise Operation

Improved fan efficiency

Unique Eco Vector sensorless control
Optidrive Eco HVAC uses advanced motor control, designed to provide the most energy efficient motor control possible. Operation with standard IM Motors, Permanent Magnet or Synchronous Reluctance motors is possible, all without requiring any feedback device or optional modules – simply change parameters to suit the connected motor, autotune and operate!

Eco Vector continuously adjusts in real time to provide the most efficient operating conditions for the load, typically reducing energy consumption by 2 – 3% compared to standard AC drives – providing similar long term costs savings to selecting a higher efficiency motor.

Energy optimised design
Optidrive Eco HVAC up to frame size 5 are designed with film capacitors, replacing the traditional electrolytic capacitors used in the DC link. Film capacitors have lower losses, and also remove the need for AC, DC or swinging chokes, improving overall drive efficiency. Efficiency is improved by up to 4% compared to standard AC drives, whilst also reducing supply current total harmonic distortion (iTHD), improving the Real Power Factor and reducing total input current, leading to cost savings on installation through reduced cable and fuse ratings and smaller supply transformer rating.

Improved Efficiency, Reduced Lifetime Costs: e.g. for a 37kW load, operating 10 hours per day, 5 days per week, 50 weeks per year, improving the efficiency by just 1% will provide an energy saving > 900kWh per year.



Dedicated to HVAC applications

Building comfort
Creating comfortable building environments without high energy costs

Air conditioning can use a significant amount of energy. In some cases it could even double energy consumption, not to mention the resultant increase in a company’s carbon footprint.

Typically the air conditioning systems in buildings are designed for maximum occupancy and peak outside ambient. This means that for the majority of time there is large scope for running the systems at reduced speed and significant money to be saved with variable speed drives.

Optidrive Eco HVAC can vary the output of your air conditioning system to meet the varying demands throughout the day.

Variable Speed Control for Pumps
Optidrive Eco HVAC provides the ideal pump control solution for chiller, circulation and cooling pumps.

Building Safety Systems
- Stairwell Pressurisation
Stairwell (escape route) pressurisation systems are being extensively employed in large buildings and complexes to help ensure the safe evacuation of occupants during a fire. Variable speed drives are playing an increasing role in maintaining pressures (of approximately 50 Pa) within these critical areas. Here Optidrive Eco HVAC is used to provide a smoke free escape by accurately maintaining the air pressure along that route. Pressures must be maintained at a high enough level that a door opened between the fire floor and the escape route does not result in smoke entering the escape route.

Equally, as doors and vents are opened along the escape route allowing air to escape the Optidrive and stairwell pressurisation system must increase output so that the required pressure is accurately maintained.

- Fume Extraction
Many buildings now incorporate dedicated smoke management and extraction systems designed to safety exact smoke in the event of a fire, these systems are designed to localise and extract smoke such that the rest of the building remains smoke free and can be evacuated safely. Here the Optidrive's Fire Mode function is critical in maintaining continued operation of the smoke extraction system for the longest permissible period.

For applications such as underground car parks the fans providing fresh air intake are often reversed in the event of a fire to provide smoke extraction. Optidrive Eco HVAC is easily configured for bi-directional fire mode operation.

- Fire Override
Fire override mode ignores signals and alarms, keeping the Optidrive Eco HVAC operating for as long as possible.
* This feature is crucial for ensuring smoke extraction from buildings in the event of a fire.
* Selectable logic means that the Optidrive Eco HVAC can be easily configured to the signal produced by your fire management system.
* With an independently set speed for fire mode operation, selectable as either forward or reverse direction, the Optidrive Eco HVAC has the flexibility to match the needs of your fire control system.
* Fire mode operation is indicated clearly on the drive display during periods of fire mode operation.
* Drive output logic can easily be configurable for indicating to external drives that fire mode is active.
* Internal clocks and timers monitoring operation in fire mode, giving clear information on usage.

Dedicated to HVAC applications

A compact and robust range of drives dedicated to HVAC.
- Internal EMC filter compliant with global EMC standards
- Multi Language Text Display installed as standard on all IP55 & IP66 models
- Maintenance interval timer and service indication
- Hand / Auto Keypad
- Pluggable terminals
- Integrated cable management
- Long Life, Dual Ball Bearing Fans

Belt Break Detection
Optidrive Eco HVAC can provide immediate warning of broken belt between motor and fan. Due to its simple and flexible configuration the feature can also be used for any loss of load condition, such as broken coupling or other mechanical failure.

Optidrive Eco HVAC monitors the load output profile throughout the speed range and compares it to normal operating conditions (established during commissioning). Sensitivity adjustment means that it is possible to detect the indications of a belt failure (such as belt slipping) prior to complete failure of the belt.

Drive Controlled Bypass
Optidrive Eco HVAC can operate as a bypass controller when installed as part of a bypass circuit. Activation of Bypass mode can be determined intelligently by the Optidrive Eco HVAC drive based on a command from the building management system. Additionally the drive can be set to automatically select bypass mode when entering into a trip condition ensuring minimal disruption to service.

Hand / Auto
Allows manual control to easily be selected in the event of an automatic control system failure or for simplified commissioning / system checks, or when a fast temporary override of the control system is required. Built‑in ‘Auto Control Selection’ allows return to automatic system control just as easily.

Noise Reduction
- Quiet Motor Operation: High switching frequency selection (up to 32kHz) ensures motor noise is minimised.
- Quiet System Mechanics: Simple skip frequency selection avoids stresses and noise caused by mechanical resonance in ducting or pipework.
- Quiet Drive Operation: Long Life Dual Ball Bearing Fans provide quiet operation in addition to extended fan life.
- Noise Reduction through Speed Control: Optimising motor speed gives significant energy savings and reduces motor noise.

Reduced Harmonic Current Distortion
Optidrive Eco HVAC uses innovative design to improve overall efficiency whilst minimising the harmonic distortion levels. All drives designed for 3 phase power supply operation1 up to frame size 5 utilise film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency. Frame size 6 and above include DC chokes and traditional electrolytic capacitors.

Optidrive Eco HVAC product range complies with the requirements of EN61000-3-12.



It can be clearly seen that the reduced DC link capacitance significantly reduces the total harmonic distortion at full load, and has a much greater benefit at part load compared to a conventional DC choke or swinging choke. This results in reduced overall input current and reduced transformer heating effect.

Optidrive Eco HVAC delivers
- Improved Efficiency, Reduced Lifetime Costs: e.g. for a 37kW load, operating 10 hours per day, 5 days per week, 50 weeks per year, improving the efficiency by just 1% will provide an energy saving > 900kWh per year
- Improved True Power Factor – No additional charges etc.
- Lower Mains Supply Current



Optidrive Eco offers improved power factor over conventional VFDs under all loads.

Options & Accessories

Peripherals to help integrate Optidrive Eco HVAC with your HVAC systems.

Optistick Smart, Rapid Commissioning Tool
- Allows copying, backup and restore of drive parameters
- Provides Bluetooth interface to a PC running OptiTools Studio or the OptiTools Mobile app on a smartphone
- Onboard NFC (Near Field Communication) for rapid data transfer



Optipad, Remote Keypad & TFT Display
IP55 panel mount operator interface.
- Clear multi-line text display
- Multiple language select
- Customisable displays



Fieldbus Interfaces
- BACnet/IP
- PROFIBUS DP
- DeviceNet
- EtherNet/IP
- Modbus TCP
- PROFINET
- EtherCAT



Plug-in Options
- Extended I/O
* Additional 3 Digital Inputs
* Additional Relay Output



Mains Isolator Option
Frame Sizes 2 & 3 can be factory ordered with a built in lockable isolator. An optional bolt on isolator is available for Frame Sizes 4 & 5.



All either copying or distribution of any material or information from asb-drives.eu website of Advanced Systems Baltic OÜ is forbidden unless it is allowed exclusively upon written authorization by the possessor of rights.
Bonfiglioli Inverters (VFD)
Fuji Electric Inverters (VFD)
Hitachi Inverters (VFD)
LS Inverters (VFD)
Mitsubishi Inverters (VFD)
ABB ACS580
ABB ACS880