Beijer Electronics BFI H3 fan and pump series

Beijer Electronics
 
    Beijer Electronics offers IP20, IP55, IP66 HVAC Inverter H3, maritime and other industrial applications and sets a new cost-effective standard for dedicated fan, pump control. Ease-of-use and innovative design combined with robust performance provides powerful flow control and reliability in a compact drive. The inverter is available in the range of 0.75-250 kW with a variety of options, including for example single or three phase input, communication boards, power switch etc. The HVAC inverter H3 provides 98% drive efficiency combined with low input harmonic current distortion compliant with EN61000-3-12. Otherwise the H3 inverter is identical with H3 regarding functionality, enclosure types, etc.


  • All drives operate at variable speed for maximum energy saving.
  • Equal runtime sharing across every pump.
  • Automatic system reconfiguration in the event of a pump fault (including the master pump).
  • Continued system operation when drives are individually powered off (including the master drive).
  • Communication and +24V control voltage shared between drives via a standard RJ45 patch lead.
  • Independent maintenance indicators for each pump.
  • Any pump can be switched to manual operation at the touch of a button, and will automatically rejoin the network when switched back to auto.
  • For waste water applications, each pump can be set for blockage/ragging detection and activate an automatic de-ragging/pump cleaning cycle.
  • Optional mains isolator with lock-off for safe pump maintenance.
  • Function configured through simple parameter set-up and intelligent-drive self-configuration.

Additional links:

 Technical documentation and Downloads
 Request additional information and get a price quote
 

Model range

BFI H3 fan and pump series (1 phase 200-240 V) / IP20

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
BFI-H3-22-0043-1F12-SN 0.75 4.3 112x221x185 reduced!
BFI-H3-22-0070-1F12-SN 1.5 7 112x221x185 reduced!
BFI-H3-22-0105-1F12-SN 2.2 10.5 112x221x185 reduced!

BFI H3 fan and pump series (3 phase 200-240 V) / IP20

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
BFI-H3-22-0043-3F12-SN 0.75 4.3 188x257x260 reduced!
BFI-H3-22-0070-3F12-SN 1.5 7 188x257x260 reduced!
BFI-H3-22-0105-3F12-SN 2.2 10.5 188x257x260 reduced!
BFI-H3-32-0180-3F12-SN 4 18 211x310x273 reduced!
BFI-H3-32-0240-3F12-SN 5.5 24 211x310x273 reduced!
BFI-H3-42-0300-3F12-TN 7.5 30 160x418x240 reduced!
BFI-H3-42-0460-3F12-TN 11 46 160x418x240 reduced!
BFI-H3-52-0610-3F12-TN 15 61 222x486x260 reduced!
BFI-H3-52-0720-3F12-TN 18.5 72 222x486x260 reduced!
BFI-H3-52-0900-3F12-TN 22 90 222x486x260 reduced!

BFI H3 fan and pump series (3 phase 380-480 V) / IP20

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
BFI-H3-24-0022-3F12-SN 0.75 2.2 110x221x185 reduced!
BFI-H3-24-0041-3F12-SN 1.5 4.1 110x221x185 reduced!
BFI-H3-24-0058-3F12-SN 2.2 5.8 110x221x185 reduced!
BFI-H3-24-0095-3F12-SN 4 9.5 110x221x185 reduced!
BFI-H3-34-0140-3F12-SN 5.5 14 131x261x205 reduced!
BFI-H3-34-0180-3F12-SN 7.5 18 131x261x205 reduced!
BFI-H3-34-0240-3F12-SN 11 24 131x261x205 reduced!
BFI-H3-44-0300-3F12-TN 15 30 160x418x240 reduced!
BFI-H3-44-0390-3F12-TN 18 39 160x418x240 reduced!
BFI-H3-44-0460-3F12-TN 22 46 160x418x240 reduced!
BFI-H3-54-0610-3F12-TN 30 61 222x486x260 reduced!
BFI-H3-54-0720-3F12-TN 37 72 222x486x260 reduced!
BFI-H3-54-0900-3F12-TN 45 90 222x486x260 reduced!
BFI-H3-84-3700-3F12-TN 200 370 482x995x480 reduced!
BFI-H3-84-4500-3F12-TN 250 450 482x995x480 reduced!

BFI H3 fan and pump series (3 phase 200-240 V) / IP55

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
BFI-H3-42-0300-3F1N-TN 7.5 30 171x450x252 reduced!
BFI-H3-42-0460-3F1N-TN 11 46 171x450x252 reduced!
BFI-H3-52-0610-3F1N-TN 15 61 235x540x270 reduced!
BFI-H3-52-0720-3F1N-TN 18.5 72 235x540x270 reduced!
BFI-H3-52-0900-3F1N-TN 22 90 235x540x270 reduced!
BFI-H3-62-1100-3F1N-TN 30 110 330x865x330 reduced!
BFI-H3-62-1500-3F1N-TN 37 150 330x865x330 reduced!
BFI-H3-72-1800-3F1N-TN 45 180 330x1280x360 reduced!
BFI-H3-72-2020-3F1N-TN 55 202 330x1280x360 reduced!
BFI-H3-72-2480-3F1N-TN 75 248 330x1280x360 reduced!

BFI H3 fan and pump series (3 phase 380-480 V) / IP55

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
BFI-H3-44-0300-3F1N-TN 15 30 171x450x252 reduced!
BFI-H3-44-0390-3F1N-TN 18 39 171x450x252 reduced!
BFI-H3-44-0460-3F1N-TN 22 46 171x450x252 reduced!
BFI-H3-54-0610-3F1N-TN 30 61 235x540x270 reduced!
BFI-H3-54-0720-3F1N-TN 37 72 235x540x270 reduced!
BFI-H3-54-0900-3F1N-TN 45 90 235x540x270 reduced!
BFI-H3-64-1100-3F1N-TN 55 110 330x865x330 reduced!
BFI-H3-64-1500-3F1N-TN 75 150 330x865x330 reduced!
BFI-H3-64-1800-3F1N-TN 90 180 330x1280x360 reduced!
BFI-H3-74-2020-3F1N-TN 110 202 330x1280x360 reduced!
BFI-H3-74-2400-3F1N-TN 132 240 330x1280x360 reduced!
BFI-H3-74-3020-3F1N-TN 160 302 330x1280x360 reduced!

BFI H3 fan and pump series (3 phase 200-240 V) / IP66

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
BFI-H3-22-0043-3F1D-TN 0.75 4.3 188x257x260 reduced!
BFI-H3-22-0070-3F1D-TN 1.5 7 188x257x260 reduced!
BFI-H3-22-0105-3F1D-TN 2.2 10.5 188x257x260 reduced!
BFI-H3-32-0180-3F1D-TN 4 18 211x310x273 reduced!
BFI-H3-32-0240-3F1D-TN 5.5 24 211x310x273 reduced!

BFI H3 fan and pump series (3 phase 380-480 V) / IP66

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
BFI-H3-24-0022-3F1D-TN 0.75 2.2 188x257x260 reduced!
BFI-H3-24-0041-3F1D-TN 1.5 4.1 188x257x260 reduced!
BFI-H3-24-0058-3F1D-TN 2.2 5.8 188x257x260 reduced!
BFI-H3-24-0095-3F1D-TN 4 9.5 188x257x260 reduced!
BFI-H3-34-0140-3F1D-TN 5.5 14 211x310x273 reduced!
BFI-H3-34-0180-3F1D-TN 7.5 18 211x310x273 reduced!
BFI-H3-34-0240-3F1D-TN 11 24 211x310x273 reduced!

BFI H3 fan and pump series (1 phase 200-240 V) / IP66

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
BFI-H3-22-0043-1F1X-TN 0.75 4.3 188x257x238 reduced!
BFI-H3-22-0070-1F1X-TN 1.5 7 188x257x238 reduced!
BFI-H3-22-0105-1F1X-TN 2.2 10.5 188x257x238 reduced!

Beijer Electronics frequency inverter BFI H3 series has an energy efficient flow control from reliable, compact drives, ideal for HVAC systems.

Beijer Electronics offers IP20, IP55 and IP66 inverters for HVAC, maritime and other industrial applications and sets a new cost-effective standard for dedicated fan and pump control. Ease-of-use and innovative design combined with robust performance provides powerful flow control and reliability in a compact drive. The HVAC Inverter H3 is available in the range of 0.75-250 kW with a variety of options, including for example single or three phase input, communication boards, power switch etc. The HVAC inverter H3, provides 98% drive efficiency combined with low input harmonic current distortion compliant with EN61000-3-12. Otherwise, the H3 inverter is identical with H3 regarding functionality, enclosure types, etc.

PID-control.

The HVAC Inverter H3 has a PID controller built-in that is fully integrated with both HVAC and energy efficient features and is packaged in a user friendly way to ensure ease-of-use and fast commissioning. Now in the majority of applications, it has become possible to eliminate the need for external controllers.

Beijer Electronics drive BFI H3 series is taking energy savings to a new level.

The third generation HVAC drive, HVAC Inverter H3, takes energy savings one step further. It reduces harmonic current distortion, associated with electronic equipment and traditional variable speed drives, to below 30% iTHD (total harmonic distortion). It also increase drive efficiency to >98% leading to energy efficiency and reduced life time costs. The proven energy saving benefits helps consumers to realize significant savings year upon year.
HVAC Inverter H3 delivers: 
- Lower mains supply current: reduced cable size, reduced fuse size, reduced transformer size 
- Improved power factor: no additional charges from the electricity supply company due to low power factor
- Improved efficiency: reduced lifetime costs. E.g. 37kW, operating 10 hours per day, 5 days per week, 50 weeks per years - power consumption is 92500kWh - 1.1% reduction is >100kWh saving 
- 0.75 kW – 250 kW power range; 3 phase 380-480 VAC input.
Beijer Electronics drive BFI H3 series is taking energy savings to a new level.
HVAC Inverter H3 power savings. With variable speed control, HVAC Inverter H3 provides instant savings. Using HVAC Inverter H3 compared to direct on line control, an estimated 20% reduction in speed results in potential energy savings of 50%. Calculation based on a typical estimated factory working week and energy costs, including estimated component and installation costs.
Beijer Electronics vfd BFI H3 series is taking energy savings to a new level.

Beijer Electronics vfd BFI H3 series is reducing energy and maintenance costs.

Coordinated pump station control, built into each HVAC Inverter H3 as standard, allows independent control of multiple pump applications. 
- All drives operate at variable speed for maximum energy saving.
- Equal runtime sharing across every pump.
- Automatic system reconfiguration in the event of a pump fault (including the master pump).
- Continued system operation when drives are individually powered off (including the master drive).
- Communication and +24V control voltage shared between drives via a standard RJ45 patch lead.
- Independent maintenance indicators for each pump.
- Any pump can be switched to manual operation at the touch of a button, and will automatically rejoin the network when switched back to auto.
- For waste water applications, each pump can be set for blockage/ragging detection and activate an automatic de-ragging/pump cleaning cycle.
- Optional mains isolator with lock-off for safe pump maintenance.
- Function configured through simple parameter set-up and intelligent-drive self-configuration.

Pump efficiency.

Built-in sleep mode with auto-boost. Sleep mode saves energy by detecting when a pump is running inefficiently and producing little useful work. The HVAC Inverter H3 can be programmed to enter into a sleep/disabled mode until the demand increases. To help prevent sleep mode oscillation, the inverter can automatically initiate a boost cycle to increase pressure on starting or stopping.

Drive controlled bypass.

Intelligent features within the HVAC Inverter H3 allow a bypass circuit to be implemented. Activation of bypass mode can be determined intelligently by the HVAC Inverter H3 drive based on a command from the building management system. The drive can be set to automatically select bypass mode when entering into a trip condition ensuring minimal disruption to service.

Avoid pump downtime with Beijer Electronics drive BFI H3 series.

- Blockage detect/clear.
HVAC Inverter H3 can detect pump blockages and trigger a programmed cleaning cycle to automatically clear them, preventing downtime.
- Pump clean/stir cycle.
Triggered by a settable period of inactivity, a configurable cleaning cycle can be run to clear sediment, ensuring the pump is ready to run when needed.
- Dry run protection.
HVAC Inverter H3 can evaluate a pump’s speed/power and shut it off or warn when the pump starts to run dry, protecting it from heat/friction damage.
- Motor preheat function.
HVAC Inverter H3 features a motor preheat function to help ensure moisture is not permitted to collect on the motor during periods of inactivity and prior to motor start-up. In addition, the motor preheat function can be used to keep condensation from developing on the motor as the motor cools down immediately following a stop. The feature is fully configurable, meaning the pump can be always available the instant it is required.
- Burst pipe protection.
After enabling the drive, the PID-feeback needs to exceed a programmed value within a programmed so as to avoid burst pipes.
Avoid pump downtime with Beijer Electronics drive BFI H3 series.
Relay cascade control (requires optional cascade module).
Variable speed duty pump with up to 4 assist pumps, the HVAC Inverter H3 can provide automatic operating time monitoring and balancing for assist pumps to share duty cycle. Runtime clocks for all fixed speed assist pumps are maintained and visible within the HVAC Inverter H3 for integration into the pump system maintenance schedules.

All either copying or distribution of any material or information from asb-drives.eu website of Advanced Systems Baltic OÜ is forbidden unless it is allowed exclusively upon written authorization by the possessor of rights.
Bonfiglioli Inverters (VFD)
Fuji Electric Inverters (VFD)
Hitachi Inverters (VFD)
LS Inverters (VFD)
Mitsubishi Inverters (VFD)
ABB ACS580
ABB ACS880