Delta's Sensorless Vector Control Drive CP2000 Series has extended the idea of energy saving and uses this principal as the basis of its design. The CP2000 is specifically designed for applications such as air blowers, pumps and HVAC drives with its intelligent PID control providing the greatest efficiency. The Sensorless Vector Control (SVC) offers timely response to load torque increase/decrease which satisfies customer requirements for load changes while enhancing motor performance. A 3-step V/F curve response is used in the variable torque environment to adequately adjust the input voltage and attain the greatest overall performance; this function is especially helpful in pumps and fans applications. It also includes additional functions for operation and protection in variable load environments, such as flying starts, auto-acceleration/deceleration, momentary power loss restarts, auto-tuning, and more. The CP2000 series provides you with the ultimate energy-saving solution for your applications.
Additional links: ![]() ![]()
|
Model range

VFD-CP series
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
VFD007CP43A-21 | 0.75 | 3 | 0-6000 | 130x250x170 | 294,00 € | |
VFD015CP43B-21 | 1.5 | 3.7 | 0-6000 | 130x250x170 | 331,00 € | |
VFD022CP43B-21 | 2.2 | 5 | 0-6000 | 130x250x170 | 351,00 € | |
VFD037CP43B-21 | 3.7 | 7.5 | 0-6000 | 130x250x170 | 375,00 € | |
VFD040CP43A-21 | 4 | 10.5 | 0-6000 | 130x250x170 | 408,00 € | |
VFD055CP43B-21 | 5.5 | 12 | 0-6000 | 130x250x170 | 481,00 € | |
VFD075CP43B-21 | 7.5 | 14 | 0-6000 | 130x250x170 | 510,00 € | |
VFD110CP43B-21 | 11 | 22.5 | 0-6000 | 190x320x190 | 658,00 € | |
VFD150CP43B-21 | 15 | 30 | 0-6000 | 190x320x190 | 774,00 € | |
VFD185CP43B-21 | 18.5 | 36 | 0-6000 | 190x320x190 | 968,00 € | |
VFD220CP43A-21 | 22 | 45 | 0-6000 | 250x400x210 | 1 123,00 € | |
VFD300CP43B-21 | 30 | 56 | 0-6000 | 250x400x210 | 1 320,00 € | |
VFD370CP43B-21 | 37 | 72 | 0-6000 | 250x400x210 | 1 616,00 € | |
VFD450CP43S-21 | 45 | 91 | 0-6000 | 330x688x275 | 1 936,00 € | |
VFD550CP43S-21 | 55 | 110 | 0-6000 | 330x688x275 | 2 323,00 € | |
VFD750CP43B-21 | 75 | 144 | 0-6000 | 330x688x275 | 2 562,00 € | |
VFD900CP43A-21 | 90 | 180 | 0-6000 | 330x688x275 | 3 299,00 € | |
VFD1100CP43A-21 | 110 | 220 | 0-6000 | 370x715.8x300 | 3 906,00 € | |
VFD1320CP43B-21 | 132 | 246 | 0-6000 | 370x715.8x300 | 4 646,00 € | |
VFD1600CP43A-21 | 160 | 310 | 0-6000 | 420x940x300 | 5 702,00 € | |
VFD1850CP43B-21 | 185 | 343 | 0-6000 | 420x940x300 | 7 008,00 € | |
VFD2200CP43A-21 | 220 | 460 | 0-6000 | 500x1240.2x397 | 9 511,00 € | |
VFD2800CP43A-00 | 280 | 530 | 0-6000 | 500x1000x397 | 16 042,00 € | |
VFD2800CP43A-21 | 280 | 530 | 0-6000 | 500x1240.2x397 | 10 282,00 € | |
VFD3150CP43C-21 | 315 | 616 | 0-6000 | 700x1745x404 | 12 434,00 € | |
VFD3550CP43C-21 | 355 | 683 | 0-6000 | 700x1745x404 | 15 511,00 € | |
VFD4000CP43C-21 | 400 | 770 | 0-6000 | 700x1745x404 | 17 995,00 € |
Delta VFD-CP2000 Water Circulation Pump Control
Features
- LCD keypad - An easy-to-use text panel with TP Editor software allows users to customize the main page screen
- Quick setting functions to support self-defined parameter groups and parameter duplication for fast and easy installation
- Modular design for flexible extension and easy maintenance
- High-speed communications include BACnet and MODBUS. Optional communication cards are available upon purchase: PROFIBUS DP, DeviceNet, MODBUS TCP, EtherNet/IP and CANopen
- Extended life cycle
- Enhanced conformal coating on PCBs for superior durability in critical environments
- Fire mode and bypass functions: continuous pressure to extract smoke when emergencies occur
- Various modes for fans/pump applications including PID control, sleep/wake up functions, flying start and skip frequency
- Multi-pumps synchronous control of up to 8 motors at one time and provides fixed amount and fixed time circulation control
- Built-in 10K steps PLC programming capacity and Real Time Clock (RTC)
Delta VFD-CP2000 Advanced Drive Technology
High Performance Variable Frequency Drive Technology
1.Sensorless Vector Control (SVC)
2.Dual rating design (Light duty & Normal duty)
3.Excellent variable torque control of asynchronous motors
Modular Design
1.Hot pluggable LCD keypad
2.I/O extension card
3.Various communication cards
4.Removable fans
Versatile Drive Control
1.Built-in PLC function
2.Built-in brake unit*
3.Networking drive system
4.Auto energy saving
Environmental Adaptability
1.50°C operation temperature
2.Built-in DC choke*
3.Coated circuit boards
4.Built-in EMC filter*
5.International safety standard CE/UL/cUL
High-Speed Network
Advanced network functions
▪ Built-in RS-485 (MODBUS)
▪ Built-in BACnet MS/TP
Various communication card options
Building Automation Applications with Delta CP2000
- 4-point adjustable V/F control - Real-time adjustment of output voltage under variable torque load environments, especially for pump and fan applications.
- Flying start and auto restart after momentary power loss functions, suitable for fan application.
- Skip frequency function avoids mechanical resonance and protects the equipment.
- Low-current protection function prevents free load operation.
- Built-in BACnet communication protocol saves wiring for building automation applications.
Delta drive CP2000 Pump series Improves Motor Performance
- Sensorless Vector Control (SVC) and auto-tuning functions to improve motor performance for variable torque load applications.
- Deceleration Energy Backup (DEB) function decelerates motor to a stop when sudden power failure occurs to protect the equipment from damage.
- Auto adjusting acceleration/deceleration speed, reduces mechanical vibration when activating and stopping the equipment and provides smooth operation.
- Energy saving control functions include PID control, sleep/wakeup mode and auto-energy saving mode.
Delta CP2000 has Built-in PLC Function
- Built-in 10K steps PLC function supports independent and distributed control when connecting to a network system for high operation flexibility.
- Real Time Clock (RTC) function facilitates the PLC program writing process for ON/OFF chronology, daylight saving operation and many other settings.
Modular Design
Powerful motor drive control functions. The modular design satisfies various system applications with higher flexibility and is easy to maintain. Accessories include input/output extension cards, communication cards, hot pluggable LCD keypad, removable terminal blocks and removable fans.
High Adaptability to Environment
► Built-in DC choke to supress harmonics*
► Built-in EMC filter for noise suppression*
► Enhanced conformal coating on PCBs for superior durability in critical environments.
► The electronic components of the drive are isolated from the cooling system to reduce heat interference. Dissipated heat can be discharged by flange-mounting installation, and forced fan cooling can import cold air into the heat sink. The heat dissipation performance is optimized by these two cooling methods.
Download manuals (all parameters)