The Unidrive M100 is a value drive that provides class leading quality and performance for open loop applications. Unidrive M100 has an easy-to-use fixed LED keypad as standard and a useful parameter guide on the front of the drive to aid understanding when setting up and interrogating. Unidrive M100 is extremely reliable due to a design based on over 40 years’ of drive knowledge, expertise and development. Build quality is ensured using world leading manufacturing processes. M100 is packed with features to keep systems running in environments as described by IEC60721-3-3 3C3 and EN60068-2-60 Meth. 4.
Additional links: Technical documentation and DownloadsRequest additional information and get a price quote |
Model range
Unidrive M100 industrial series (1 phase 100-120 V)
Model | Capacity, kW |
Current, A |
Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|
M10x-011 00017A | 0,25 | 1.7 | 75x137x130 | reduced! | |
M10x-011 00024A | 0,37 | 2.4 | 75x137x130 | reduced! | |
M10x-021 00042A | 0,75 | 4.2 | 75x180x150 | reduced! | |
M10x-021 00056A | 1,1 | 5.6 | 75x180x150 | reduced! |
Unidrive M100 industrial series (1 phase 200-240 V)
Model | Capacity, kW |
Current, A |
Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|
M10x-012 00017A | 0,25 | 1.7 | 75x137x130 | reduced! | |
M10x-012 00024A | 0,37 | 2.4 | 75x137x130 | reduced! | |
M10x-012 00033A | 0,55 | 3.3 | 75x137x130 | reduced! | |
M10x-012 00042A | 0,75 | 4.2 | 75x137x130 | 124,00 € | |
M10x-022 00056A | 1,1 | 5.6 | 75x180x150 | reduced! | |
M10x-022 00075A | 1,5 | 7.5 | 75x180x150 | reduced! | |
M10x-032 00100A | 2,2 | 10 | 90x200x160 | reduced! | |
M10x-042 00133A | 3 | 13.3 | 115x245x175 | reduced! |
Unidrive M100 industrial series (3 phase 200-240 V)
Model | Capacity, kW |
Current, A |
Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|
M10x-022 00024A | 0,37 | 2.4 | 75x180x150 | reduced! | |
M10x-022 00033A | 0,55 | 3.3 | 75x180x150 | reduced! | |
M10x-022 00042A | 0,75 | 4.2 | 75x180x150 | reduced! | |
M10x-022 00056A | 1,1 | 5.6 | 75x180x150 | 228,00 € | |
M10x-022 00075A | 1,5 | 7.5 | 75x180x150 | reduced! | |
M10x-032 00100A | 2,2 | 10 | 90x200x160 | reduced! | |
M10x-042 00133A | 3 | 13.3 | 115x245x175 | reduced! | |
M10x-042 00176A | 4 | 17.6 | 115x245x175 | reduced! |
Unidrive M100 industrial series (3 phase 380-480 V)
Model | Capacity, kW |
Current, A |
Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|
M10x-024 00013A | 0,37 | 1.3 | 75x180x150 | reduced! | |
M10x-024 00018A | 0,55 | 1.8 | 75x180x150 | reduced! | |
M10x-024 00023A | 0,75 | 2.3 | 75x180x150 | reduced! | |
M10x-024 00032A | 1,1 | 3.2 | 75x180x150 | reduced! | |
M10x-024 00041A | 1,5 | 4.1 | 75x180x150 | 360,00 € | |
M10x-034 00056A | 2,2 | 5.6 | 90x200x160 | reduced! | |
M10x-034 00073A | 3 | 7.3 | 90x200x160 | 437,00 € | |
M10x-034 00094A | 4 | 9.4 | 90x200x160 | reduced! | |
M10x-044 00135A | 5,5 | 13.5 | 115x245x175 | reduced! | |
M10x-044 00170A | 7,5 | 17 | 115x245x175 | reduced! |
Emerson frequency inverter Unidrive M100 AC series at a glance.
Value drive with quality and performance for open loop industrial automation applications.
As part of the Unidrive M family, dedicated to Industrial Automation, M100 delivers an economical open loop drive for general applications, with Control Techniques’ proven quality and class leading motor operation.
Install and configure quickly and easily.
Unidrive M100 has an easy-to-use fixed LED keypad as standard and a useful parameter guide on the front of the drive to aid understanding when setting up and interrogating. Parameter sets can be easily transferred between drives using an SD card with AI-Back-up or AISmart Adaptor. Fast install DIN rail mounting is supported up to 1.5 kW (2 hp).
Transfer parameters without mains power.
For fast, serial machine production, the AI-Back-up or AISmart Adaptor option can be powered by 24 V to transfer parameter sets to and from standard SD Cards.
Minimize downtime with robust and reliable design.
Unidrive M100 is extremely reliable due to a design based on over 40 years’ of drive knowledge, expertise and development. Build quality is ensured using world leading manufacturing processes. M100 is packed with features to keep systems running in environments as described by IEC60721-3-3 3C3 and EN60068-2-60 Meth. 4.
- PCBs have conformal coating to further increase resilience to harsh environmental conditions
- A patented air flow system cools the drive more effectively and protects internal components
- Wide supply voltage tolerance keeps drive operation smooth in areas where supplies are variable
- Intelligent 3 speed user-replaceable cooling fan with patented fan-fail detection circuit.
- Trip avoidance features take intelligent action instead of tripping out critical processes. For example: Load shedding reduces speed at current limits, supply loss ride-through keeps running during brown outs
- Derating values are available so that M100 can be run in higher temperature environments
- High overload capability - 150 % for 60 s
- Ingress protection up to IP21 - UL open class (NEMA 1) compliance.
Reduce application size and cost.
Unidrive M100’s compact drive dimensions are among the smallest in class at every power rating.
Emerson Unidrive M100 series drive environmental safety and electrical conformance.
- IP21 / UL open class (NEMA 1).
- IP20 when the AI-Back-up Adaptor is fitted.
- UL TYPE 1 compliance requires the appropriate Conduit kit to be fitted.
- Ambient temperature -20 °C (-4 °F) to 40 °C (104 °F) as standard. Output current derating required at ambient temperatures >40 °C (104 °F).
- Storage temperature -40 °C to 60 °C (-40 °F to 140 °F).
- Humidity 95 % maximum (non-condensing) at 40 °C (104 °F) in accordance with EN/IEC 60068-2-78 and ANSI/EIA-364-31.
- EN/IEC 60068-2-60, Method 4 Corrosive gas.
- Altitude: 0 to 3000 m (0 to 9843 ft), derate 1 % per 100 m (328 ft) between 1000 m and 3000 m (3281 ft and 9843 ft).
- Random Vibration: Tested in accordance with EN/ IEC 60068-2-64.
- Mechanical Shock: Tested in accordance with EN/ IEC 60068-2-29.
- Electromagnetic Immunity complies with EN/IEC 61800-3 and EN/IEC 61000-6-2.
- With onboard EMC filter, complies with EN/IEC 61800-3 (2nd environment).
- EN/IEC 61000-6-3 and EN/IEC 61000-6-4 with optional footprint EMC filter.
- EN/IEC 61800-5-1 Electrical Safety.
- EN/IEC 61131-2 I/O.
- UL 508C Electrical Safety.