Hyundai Heavy Industries (HHI) N800-Series is part of HHI’s low voltage drive family which offers a wide power range at various voltages to cover a variety of applications from pump, fan, conveyor and compressor applications through to demanding machinery and marine solutions. N800A AC drive is equipped with smart new benefits from functional safety with Safe Torque Off to prevent the drive from generating torque on the motor shaft, Safe Stop1, and ATEX certified motor over-temperature protection.
Additional links: Technical documentation and DownloadsRequest additional information and get a price quote |
Model range
N800A Series (3 phase 208-240 V, IP21) * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
N800A0100-3L-0003-2 | 0,37 | 2.6 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0004-2 | 0,55 | 3.7 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0007-2 | 0,75 | 4.8 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0008-2 | 1,1 | 6.6 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0011-2 | 1,5 | 8 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0012-2 | 2,2 | 9.6 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0018-2 | 3 | 12.5 | 0.1-3000 | 144x419x214 | reduced! | |
N800A0100-3L-0024-2 | 4 | 18 | 0.1-3000 | 144x419x214 | reduced! | |
N800A0100-3L-0031-2 | 5,5 | 25 | 0.1-3000 | 144x419x214 | reduced! | |
N800A0100-3L-0048-2 | 7,5 | 31 | 0.1-3000 | 195x557x229 | reduced! | |
N800A0100-3L-0062-2 | 11 | 48 | 0.1-3000 | 195x557x229 | reduced! | |
N800A0100-3L-0075-2 | 15 | 62 | 0.1-3000 | 237x660x259 | reduced! | |
N800A0100-3L-0088-2 | 18,5 | 75 | 0.1-3000 | 237x660x259 | reduced! | |
N800A0100-3L-0105-2 | 22 | 88 | 0.1-3000 | 237x660x259 | reduced! | |
N800A0100-3L-0140-2 | 30 | 114 | 0.1-3000 | 290x966x343 | reduced! | |
N800A0100-3L-0170-2 | 37 | 140 | 0.1-3000 | 290x966x343 | reduced! | |
N800A0100-3L-0205-2 | 45 | 170 | 0.1-3000 | 290x966x343 | reduced! | |
N800A0100-3L-0261-2 | 55 | 211 | 0.1-3000 | 480x1150x365 | reduced! | |
N800A0100-3L-0310-2 | 75 | 251 | 0.1-3000 | 480x1150x365 | reduced! |
N800A Series (3 phase 208-240 V, IP00) * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
N800A0100-3L-0140-2 | 30 | 114 | 0.1-3000 | 290x794x343 | reduced! | |
N800A0100-3L-0170-2 | 37 | 140 | 0.1-3000 | 290x794x343 | reduced! | |
N800A0100-3L-0205-2 | 45 | 170 | 0.1-3000 | 290x794x343 | reduced! | |
N800A0100-3L-0261-2 | 55 | 211 | 0.1-3000 | 480x970x365 | reduced! | |
N800A0100-3L-0310-2 | 75 | 251 | 0.1-3000 | 480x970x365 | reduced! |
N800A Series (3 phase 380-500 V, IP21) * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
N800A0100-3L-0003-5 | 0,75 | 2.6 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0004-5 | 1,1 | 3.4 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0005-5 | 1,5 | 4.3 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0008-5 | 2,2 | 5.6 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0009-5 | 3 | 8 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0012-5 | 4 | 9.6 | 0.1-3000 | 128x328x190 | reduced! | |
N800A0100-3L-0016-5 | 5,5 | 12 | 0.1-3000 | 144x419x214 | reduced! | |
N800A0100-3L-0023-5 | 7,5 | 16 | 0.1-3000 | 144x419x214 | reduced! | |
N800A0100-3L-0031-5 | 11 | 23 | 0.1-3000 | 144x419x214 | reduced! | |
N800A0100-3L-0038-5 | 15 | 31 | 0.1-3000 | 195x557x229 | reduced! | |
N800A0100-3L-0046-5 | 18,5 | 38 | 0.1-3000 | 195x557x229 | reduced! | |
N800A0100-3L-0061-5 | 22 | 46 | 0.1-3000 | 195x557x229 | reduced! | |
N800A0100-3L-0072-5 | 30 | 61 | 0.1-3000 | 237x660x259 | reduced! | |
N800A0100-3L-0087-5 | 37 | 72 | 0.1-3000 | 237x660x259 | reduced! | |
N800A0100-3L-0105-5 | 45 | 87 | 0.1-3000 | 237x660x259 | reduced! | |
N800A0100-3L-0140-5 | 55 | 105 | 0.1-3000 | 290x966x343 | reduced! | |
N800A0100-3L-0170-5 | 75 | 140 | 0.1-3000 | 290x966x343 | reduced! | |
N800A0100-3L-0205-5 | 90 | 170 | 0.1-3000 | 290x966x343 | reduced! | |
N800A0100-3L-0261-5 | 110 | 205 | 0.1-3000 | 480x1150x365 | reduced! | |
N800A0100-3L-0310-5 | 132 | 251 | 0.1-3000 | 480x1150x365 | reduced! |
N800A Series (3 phase 380-500 V, IP00) * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
N800A0100-3L-0140-5 | 55 | 105 | 0.1-3000 | 290x794x343 | reduced! | |
N800A0100-3L-0170-5 | 75 | 140 | 0.1-3000 | 290x794x343 | reduced! | |
N800A0100-3L-0205-5 | 90 | 170 | 0.1-3000 | 290x794x343 | reduced! | |
N800A0100-3L-0261-5 | 110 | 205 | 0.1-3000 | 480x970x365 | reduced! | |
N800A0100-3L-0310-5 | 132 | 251 | 0.1-3000 | 480x970x365 | reduced! | |
N800A0100-3L-0385-5 | 160 | 310 | 0.1-3000 | 506x980x525 | reduced! | |
N800A0100-3L-0460-5 | 200 | 385 | 0.1-3000 | 506x980x525 | reduced! | |
N800A0100-3L-0590-5 | 280 | 520 | 0.1-3000 | 506x980x525 | reduced! |
Smart Integration to Your Plant Automation with Hyundai frequency inverter N800A series
Fieldbus
- N800A is easily integrated with your plant’s automation system using built-in Modbus RTU (RS485) or Modbus TCP (Ethernet).
- Software options: Ethernet IP, Profinet I/O Click in fieldbus options: Profibus-DP, Devicenet, LonWorks, CANopen
Built-In Ethernet
- Ethernet is the preferred protocol in industries today. That makes the N800A an economical choice.
- No additional options or gateways are needed for the communication with process automation due to its unique built- in Ethernet for local or remote wireless monitoring.
Protective Features of Hyundai drive N800A series
Safe Torque Off, Safe Stop1
- Safe Torque Off (STO) prevents the drive from generating torque on the motor shaft and prevents unintentional start-ups with stop category0, EN 60204-1.
- Safe Stop1 (SS1) initiates motor deceleration and initiates the STO function after an application specific time delay with stop category1, EN 60204-1.
ATEX Certified Thermistor Input
Certified and compliant with the European ATEX directive, 94 / 9 / EC, the integrated thermistor input is specially designed for the temperature supervision of motors that are placed in potentially explosive gas, vapor. If over-heating is detected, the drive immediately stops feeding energy to the motor.
Easier Commissioning with Hyundai vfd N800A series
User-Friendly Keypad
N800A’s keypad has ensured that the user interface is simple and intuitive to use due to keypad’s well-structured menu system that allows for fast commissioning and trouble-free operation.
- Graphical keypad with multiple language support
- 9 signals can be monitored at the same time on a single multi-monitor page and is configurable to either 9,6 or 4 signals
- 3 color LED status indication on the control unit: blinking green = ready, green = run, red = fault 3
- Trend display for two signals at the same time
Quick Start Wizards
Quick Start 8 Wizards ensures easy set up application. Easy diagnostic with help in plain text is provided for each parameter, signal and fault.
- Startup Wizard - For fast setup of basic pump or fan applications
- PID Mini-Wizard - For easy commissioning of internal PID Controller
- Multi-Pump Wizard - For easy commissioning of Multi-Pump system
- Fire Mode Wizard - For easy commissioning of Fire Mode function
Easy Installation
- Both IP21 / UL Type1 and IP54 / UL Type12 units with the same footprint.
- Compact IP54 / UL Type12 units can be installed side by side and require no additional space between them.
- Frame size MR8 - 10 are available as IP00 for cabinet installation.
- Flange mounting option enables through-hole mounting in the enclosure with the heat sink remaining on the outside of the enclosure.
Built-in PLC Functionality
N800A comes equipped with a built-in PLC functionality that enables the drive to adapt to almost any function requiring I/O and control logic. Configurations can be copied using PC tool as part of the normal parameter list.