Siemens Micromaster 420 is a universal drive for three-phase networks with fieldbus connectivity. The drive has a modular design and various options complement a wide range of standard features. Simply plug in the operator panel and communication module without using any tools. As with the other drives in this series, the terminal connections are made easy thanks to the screwless control terminals.


  • Easy, guided start-up
  • Modular construction allows maximum configuration flexibility
  • Three fully programmable isolated digital inputs
  • Low-noise motor operation through high pulse frequency, adjustable (observe derating if necessary)
  • Complete inverter and motor protection
  • EMC filter, Class A/B option
  • Latest IGBT technology
  • Digital microprocessor control
  • Internal PI controller for simple process control
  • Inverter overtemperature protection
  • Motor protection using PTC via digital input (possible with supplementary circuit)

Model range

Micromaster 420 general purpose series ( 1 phase 200-240 V) * Discontinued series! Ask for new version or replacement!

Model Capacity,
kW
Current,
A
Deceleration time, sec Dimensions
(W x H x D), mm
Price
6SE6420-2UC11-2AA1 0,12 0.9 0-650 73х173х149 reduced!
6SE6420-2UC12-5AA1 0,25 1.7 0-650 73х173х149 reduced!
6SE6420-2UC13-7AA1 0,37 2.3 0-650 73х173х149 reduced!
6SE6420-2UC15-5AA1 0,55 3 0-650 73х173х149 reduced!
6SE6420-2UC17-5AA1 0,75 3.9 0-650 73х173х149 reduced!
6SE6420-2UC21-1BA1 1,1 5.5 0-650 149х202х172 reduced!
6SE6420-2UC21-5BA1 1,5 7.4 0-650 149х202х172 reduced!
6SE6420-2UC22-2BA1 2,2 10.4 0-650 149х202х172 reduced!
6SE6420-2UC23-0CA1 3 13.6 0-650 185x245x195 reduced!

Micromaster 420 general purpose series ( 3 phase 200-240 V) * Discontinued series! Ask for new version or replacement!

Model Capacity,
kW
Current,
A
Deceleration time, sec Dimensions
(W x H x D), mm
Price
6SE6420-2UC11-2AA1 0,12 0.9 0-650 73x173x149 reduced!
6SE6420-2UC12-5AA1 0,25 1.7 0-650 73x173x149 reduced!
6SE6420-2UC13-7AA1 0,37 2.3 0-650 73x173x149 reduced!
6SE6420-2UC15-5AA1 0,55 3 0-650 73x173x149 reduced!
6SE6420-2UC17-5AA1 0,75 3.9 0-650 73x173x149 reduced!
6SE6420-2UC21-1BA1 1,1 5,5 0-650 149x202x172 reduced!
6SE6420-2UC21-5BA1 1,5 7.4 0-650 149x202x172 reduced!
6SE6420-2UC22-2BA1 2,2 10.4 0-650 149x202x172 reduced!
6SE6420-2UC23-0CA1 3 13.6 0-650 185x245x195 reduced!
6SE6420-2UC24-0CA1 4 17.5 0-650 185x245x195 reduced!
6SE6420-2UC25-5CA1 5,5 22 0-650 185x245x195 reduced!

Micromaster 420 general purpose series ( 3 phase 380-480 V) * Discontinued series! Ask for new version or replacement!

Model Capacity,
kW
Current,
A
Deceleration time, sec Dimensions
(W x H x D), mm
Price
6SE6420-2UD13-7AA1 0,37 1.2 0-650 73x173x149 reduced!
6SE6420-2UD15-5AA1 0,55 1.5 0-650 73x173x149 reduced!
6SE6420-2UD17-5AA1 0,75 2.1 0-650 73x173x149 reduced!
6SE6420-2UD21-1AA1 1,1 3 0-650 73x173x149 reduced!
6SE6420-2UD21-5AA1 1,5 4 0-650 73x173x149 reduced!
6SE6420-2UD22-2BA1 2,2 5.9 0-650 149x202x172 reduced!
6SE6420-2UD23-0BA1 3 7.7 0-650 149x202x172 reduced!
6SE6420-2UD24-0BA1 4 10.2 0-650 149x202x172 reduced!
6SE6420-2UD25-5CA1 5,5 13.2 0-650 185x245x195 reduced!
6SE6420-2UD27-5CA1 7,5 19 0-650 185x245x195 reduced!
6SE6420-2UD31-1CA1 11 26 0-650 185x245x195 reduced!

Siemens frequency inverter Micromaster 420 series description.

Application.
The MICROMASTER 420 inverter is suitable for a variety of variable-speed drive applications. It is especially suitable for applications with pumps, fans and in conveyor systems. It is the ideal cost-optimized frequency inverter solution. The inverter is especially characterized by its customer-oriented performance and easeof-use. Its large mains voltage range enables it to be used all over the world.
Design.
The MICROMASTER 420 inverter has a modular design. The operator panels and communication modules can be easily exchanged without requiring any tools.
Main characteristics. 
- Easy, guided start-up 
- Modular construction allows maximum configuration flexibility 
- Three fully programmable isolated digital inputs 
- One analog input (0 V to 10 V, scaleable) or for use as 4th digital input 
- One programmable analog output (0 mA to 20 mA) 
- One programmable relay output (30 V DC/5 A resistive load; 250 V AC/2A inductive load) 
- Low-noise motor operation through high pulse frequency, adjustable (observe derating if necessary) 
- Complete protection for motor and inverter.
Options.
- EMC filter, Class A/B 
- LC filter 
- Line commutating chokes 
- Output chokes 
- Gland plates
- Basic Operator Panel (BOP) for parameterizing the inverter 
- Advanced Operator Panel (AOP) with multi-language plain text display 
- Asian Advanced Operator Panel (AAOP) with Chinese and English plain text display 
- Cyrillic Advanced Operator Panel (CAOP) with Cyrillic, German and English plain text display 
- Communication modules – PROFIBUS – DeviceNet – CANopen 
- PC connection kits 
- Mounting kits for installing the operator panels in the control cabinet doors 
- PC start-up programs executable under Windows 98 and NT/2000/ME/ XP Professional 
- TIA integration with Drive ES
Mechanical features.
- Modular design 
- Operating temperature –10 °C to +50 °C (+14 °F to +122 °F) 
- Compact housing as a result of high power density 
- Easy cable connection, mains and motor connections are separated for optimum electromagnetic compatibility 
- Detachable operator panels 
- Screwless control terminals

Siemens drive Micromaster 420 series operating temperature.

Siemens drive Micromaster 420 series operating temperature.

Siemens vfd Micromaster 420 series design.

- A maximum of two footprint components plus inverter are permissible.
- If an LC filter is used, it must be mounted directly on the wall of the control cabinet due to weight reasons. If an LC filter of frame size C is used, therefore, only one footprint component is permissible. If a line choke and LC filter are used, the line choke must be located on the left of the inverter. Required distance between line choke and inverter: 75 mm.
- The EMC filter must be mounted directly below the frequency inverter if possible. 
- If mounted on the side, the line-side components are to be mounted to the left of the frequency inverter whereas the output-side components are to be mounted to the right of the frequency inverter.
Siemens vfd Micromaster 420 series design.

Siemens frequency inverter Micromaster 420 series variant independent options.

Basic Operator Panel (BOP).
With the BOP, individual parameter settings can be made. Values and units are shown on a 5-digit display. A BOP can be used for several inverters. It can be directly mounted on the inverter or in a control cabinet door using a mounting kit.
Siemens frequency inverter Micromaster 420 series variant independent options.
Advanced Operator Panel (AOP).
The AOP enables parameter kits to be read out of the inverter or to be written into the inverter (upload/download). Different parameter kits can be stored in the AOP. It has a plain text display with the possibility of switching between several languages.
Siemens drive Micromaster 420 series variant independent options.
Up to 30 inverters can be controlled from an AOP via USS. It can be directly mounted on the inverter or in a control cabinet door using a mounting kit.
Asian Advanced Operator Panel (AAOP).
The AAOP is the Chinese version of the AOP operator panel. It has an enhanced display and supports the operating languages of Chinese (simplified) and English.
Siemens vfd Micromaster 420 series variant independent options.
Cyrillic Advanced Operator Panel (CAOP).
The CAOP is the Cyrillic version of the AOP Advanced Operator Panel. It supports the Cyrillic, German and English operator languages.
PROFIBUS module.
For a complete PROFIBUS connection with up to 12 Mbaud. Remote control of the inverter is possible with the PROFIBUS module. Remote control and operation at the inverter can be combined using an operator panel plugged onto the PROFIBUS module. The PROFIBUS module can be supplied by an external 24 V DC power supply and is thus also active when the inverter is disconnected from the power supply. Connection by means of a 9-pin Sub-D connector (available as an option).
DeviceNet module.
For networking the inverters to the DeviceNet fieldbus system widely used on the American market. A maximum transmission rate of 500 Kbaud is possible. Remote control of the inverter is possible with the DeviceNet module. Remote control and operation at the inverter can be combined using an operator panel plugged onto the DeviceNet module. The connection to the DeviceNet bus system is made using a 5-pin connector with terminal strip.
CANopen module.
Using the CANopen communications module, an inverter can be linked to the CANopen fieldbus system and remote control is then possible. Remote control and operation at the inverter can be combined using an operator panel plugged onto the CANopen module. The module is connected to the bus system through a 9-pin Sub-D connector.