The enclosed Vacon NXC AC drive solution is compact and well tested. It’s perfect for when a flexible, robust and serviceable industrial AC drive is needed, and comes with a power range of 110 kW to 2 MW. VACON NXC drives have reliable thermal handling for the enclosure, extending the lifetime of the frequency converter and ensuring tough environments don’t overly affect application processes. The control compartment is easily accessible, includes Vacon’s removable keypad, and enclosures come with lifting lugs to aid installation.
Additional links: Technical documentation and DownloadsRequest additional information and get a price quote |
Model range
Vacon NXС series, regenerative drive, voltage 380-500 V (3 phase)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
NXC 0261 5A2L0RSF | 132 | 261 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0300 5A2L0RSF | 160 | 300 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0385 5A2L0RSF | 200 | 385 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0460 5A2L0RSF | 250 | 460 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0520 5A2L0RSF | 250 | 520 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0650 5A2L0RSF | 355 | 650 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 0730 5A2L0RSF | 400 | 730 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 0820 5A2L0RSF | 450 | 820 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 0920 5A2L0RSF | 500 | 920 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 1030 5A2L0RSF | 560 | 1030 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 1150 5A2L0RSF | 630 | 1150 | 0-3000 | 2206x2275x605 | reduced! | |
NXC 1300 5A2L0RSF | 710 | 1300 | 0-3000 | 2206x2275x605 | reduced! | |
NXC 1450 5A2L0RSF | 800 | 1450 | 0-3000 | 2206x2275x605 | reduced! | |
NXC 1770 5A2L0RSF | 1000 | 1700 | 0-3000 | 4406x2275x605 | reduced! | |
NXC 2150 5A2L0RSF | 1200 | 2150 | 0-3000 | 4406x2275x605 | reduced! | |
NXC 2700 5A2L0RSF | 1500 | 2700 | 0-3000 | 4406x2275x605 | reduced! |
Vacon NXС series, regenerative drive, voltage 500-690 V (3 phase)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
NXC 0125 6A2L0RSF | 110 | 125 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0144 6A2L0RSF | 132 | 144 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0170 6A2L0RSF | 160 | 170 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0208 6A2L0RSF | 200 | 208 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0261 6A2L0RSF | 250 | 261 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0325 6A2L0RSF | 315 | 325 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0385 6A2L0RSF | 355 | 385 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0416 6A2L0RSF | 400 | 416 | 0-3000 | 1006x2275x605 | reduced! | |
NXC 0460 6A2L0RSF | 450 | 460 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 0502 6A2L0RSF | 500 | 502 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 0590 6A2L0RSF | 560 | 590 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 0650 6A2L0RSF | 630 | 650 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 0750 6A2L0RSF | 710 | 750 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 0820 6A2L0RSF | 800 | 820 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 0920 6A2L0RSF | 900 | 920 | 0-3000 | 2206x2275x605 | reduced! | |
NXC 1030 6A2L0RSF | 1000 | 1030 | 0-3000 | 2206x2275x605 | reduced! | |
NXC 1180 6A2L0RSF | 1150 | 1180 | 0-3000 | 2206x2275x605 | reduced! | |
NXC 1500 6A2L0RSF | 1500 | 1500 | 0-3000 | 4406x2275x605 | reduced! | |
NXC 1900 6A2L0RSF | 1800 | 1900 | 0-3000 | 4406x2275x605 | reduced! | |
NXC 2250 6A2L0RSF | 2000 | 2250 | 0-3000 | 4406x2275x605 | reduced! |
Vacon NXС 6 - pulse network series, voltage 380-500 V (3 phase)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
NXC 0261 5A2H0SSF | 132 | 261 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0300 5A2H0SSF | 160 | 300 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0385 5A2L0SSF | 200 | 385 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0460 5A2L0SSF | 250 | 460 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0520 5A2L0SSF | 250 | 520 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0590 5A2L0SSF | 315 | 590 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0650 5A2L0SSF | 355 | 650 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0730 5A2L0SSF | 400 | 730 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0820 5A2L0SSF | 450 | 820 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 0920 5A2L0SSF | 500 | 920 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 1030 5A2L0SSF | 560 | 1030 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 1150 5A2L0SSF | 630 | 1150 | 0-3000 | 1406x2275x605 | reduced! | |
NXC 1300 5A2L0SSF | 710 | 1300 | 0-3000 | 1606x2275x605 | reduced! | |
NXC 1450 5A2L0SSF | 800 | 1450 | 0-3000 | 1606x2275x605 | reduced! | |
NXC 1770 5A2L0SSF | 1000 | 1770 | 0-3000 | 2806x2275x605 | reduced! | |
NXC 2150 5A2L0SSF | 1200 | 2150 | 0-3000 | 2806x2275x605 | reduced! |
Vacon NXС 6 - pulse network series, voltage 500-690 V (3 phase)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
NXC 0125 6A2L0SSF | 110 | 125 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0144 6A2L0SSF | 132 | 144 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0170 6A2L0SSF | 160 | 170 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0208 6A2L0SSF | 200 | 208 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0261 6A2L0SSF | 250 | 261 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0325 6A2L0SSF | 315 | 325 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0385 6A2L0SSF | 355 | 385 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0416 6A2L0SSF | 400 | 416 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0460 6A2L0SSF | 450 | 460 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0502 6A2L0SSF | 500 | 502 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0590 6A2L0SSF | 560 | 590 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0650 6A2L0SSF | 630 | 650 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 0750 6A2L0SSF | 710 | 750 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 0820 6A2L0SSF | 800 | 820 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 0920 6A2L0SSF | 900 | 920 | 0-3000 | 1406x2275x605 | reduced! | |
NXC 1030 6A2L0SSF | 1000 | 1030 | 0-3000 | 1406x2275x605 | reduced! | |
NXC 1180 6A2L0SSF | 1150 | 1180 | 0-3000 | 1406x2275x605 | reduced! | |
NXC 1500 6A2L0SSF | 1500 | 1500 | 0-3000 | 2406x2275x605 | reduced! | |
NXC 1900 6A2L0SSF | 1800 | 1900 | 0-3000 | 2806x2275x605 | reduced! | |
NXC 2250 6A2L0SSF | 2000 | 2250 | 0-3000 | 2806x2275x605 | reduced! |
Vacon NXС 12 - pulse network series, voltage 380-500 V (3 phase)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
NXC 0385 5A2L0TSF | 200 | 385 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0460 5A2L0TSF | 250 | 460 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0520 5A2L0TSF | 250 | 520 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0590 5A2L0TSF | 315 | 590 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0650 5A2L0TSF | 355 | 650 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0730 5A2L0TSF | 400 | 730 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0820 5A2L0TSF | 450 | 820 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 0920 5A2L0TSF | 500 | 920 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 1030 5A2L0TSF | 560 | 1030 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 1150 5A2L0TSF | 630 | 1150 | 0-3000 | 1406x2275x605 | reduced! | |
NXC 1300 5A2L0TSF | 710 | 1300 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 1450 5A2L0TSF | 800 | 1450 | 0-3000 | 2006x2275x605 | reduced! | |
NXC 1770 5A2L0TSF | 1000 | 1770 | 0-3000 | 2806x2275x605 | reduced! | |
NXC 2150 5A2L0TSF | 1200 | 2150 | 0-3000 | 2806x2275x605 | reduced! |
Vacon NXС 12 - pulse network series, voltage 500-690 V (3 phase)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
NXC 0261 6A2L0TSF | 250 | 261 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0325 6A2L0TSF | 315 | 325 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0385 6A2L0TSF | 355 | 385 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0416 6A2L0TSF | 400 | 416 | 0-3000 | 606x2275x605 | reduced! | |
NXC 0460 6A2L0TSF | 450 | 460 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0502 6A2L0TSF | 500 | 502 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0590 6A2L0TSF | 560 | 590 | 0-3000 | 806x2275x605 | reduced! | |
NXC 0650 6A2L0TSF | 630 | 650 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 0750 6A2L0TSF | 710 | 750 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 0820 6A2L0TSF | 800 | 820 | 0-3000 | 1206x2275x605 | reduced! | |
NXC 0920 6A2L0TSF | 900 | 920 | 0-3000 | 1406x2275x605 | reduced! | |
NXC 1030 6A2L0TSF | 1000 | 1030 | 0-3000 | 1406x2275x605 | reduced! | |
NXC 1180 6A2L0TSF | 1150 | 1180 | 0-3000 | 1406x2275x605 | reduced! | |
NXC 1500 6A2L0TSF | 1500 | 1500 | 0-3000 | 2806x2275x605 | reduced! | |
NXC 1900 6A2L0TSF | 1800 | 1900 | 0-3000 | 2806x2275x605 | reduced! | |
NXC 2250 6A2L0TSF | 2000 | 2250 | 0-3000 | 2806x2275x605 | reduced! |
Vacon frequency inverter NXC series is designed to meet the most demanding requirements for flexibility, robustness, compactness and service-friendliness.
Exceptional performance.
Our enclosed Vacon NXC variable speed AC drives are compact and well tested to meet harsh operating conditions. They are typically put to work in segments, such as mining, oil & gas, water & wastewater. The reliable thermal handling of the enclosure guarantees extended lifetime of the frequency converter and trouble-free operation in tough environments. Approved EMC solutions ensure reliable operation of the converter without disturbing other electrical equipment.
User-friendly.
Vacon NXC features an easily accessible control compartment for relays, auxiliary terminals and other equipment and ample space around the power terminals allows for easy installation and connection of power cables. Our trademark handy keypad is located on the door with additional door options including indicators, meters and switches. Bottom plates and earthing claps for 360 degree earthing of motor cables are provided as standard.
Service-friendly.
Vacon NXC enclosures are easy to install with lifting lugs for easy handling and can be wall-mounted or freestanding. Vacon NXP power units are rail-mounted for easy pull-out, and the optional pull-out jig enables hassle-free servicing of the power unit. No additional cooling fans are required in the enclosure IP21/IP54 and the fans can be easily replaced without having to remove the power unit.
EMC selection table for Vacon drive NXC series.
The product family standard EN 61800-3 sets limits for both emissions and immunity to radio frequency disturbances. The environment has been divided into the first and second environments; in practice, public and industrial networks, respectively. Radio Frequency Interference (RFI) filters are typically required to meet the EN 61800-3 standard. These filters are integrated in the Vacon NXP as standard. The 208–240 V and 380–500 V ranges of the Vacon NXP (FR4-FR9) meet the requirements of the first and second environments (H level: EN 61800-3(2004), category C2). No additional RFI filters or cabinets are required. The FR10-FR14 and the 500-690 V ranges of the Vacon NXP meet the requirements of the second environment (L-level: EN 61800-3(2004), category C3). The units in the frame sizes FR4, FR5 and FR6 (with a voltage range from 380 to 500 V) are also available with extremely low-emission integrated EMC filters (C level: EN 61800-3 (2004), category C1). This is sometimes required in very sensitive locations, such as hospitals.