Frequency inverters A1000 multi-purpose series provides significant advantages due to the excellent characteristics of the motor control (both induction and synchronous), careful attitude to the environment and energy savings.
Additional information: Technical documentationRequest additional information and price |
Model range
A1000 series (3 phase / 400V), IP 54, wall mounting, mains switch * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
CIMR-AC4A0044TAA-0095 | 18,5 | 39 | 0-6000 | 400х700х292 | reduced! | |
CIMR-AC4A0058TAA-0095 | 22 | 45 | 0-6000 | 465х750х331 | reduced! | |
CIMR-AC4A0072TAA-0095 | 30 | 60 | 0-6000 | 465х750х331 | reduced! | |
CIMR-AC4A0088TAA-0095 | 37 | 75 | 0-6000 | 555х950х375 | reduced! | |
CIMR-AC4A0103TAA-0095 | 45 | 91 | 0-6000 | 555х950х375 | reduced! | |
CIMR-AC4A0139TAA-0095 | 55 | 112 | 0-6000 | 555х950х375 | reduced! | |
CIMR-AC4A0165TAA-0095 | 75 | 150 | 0-6000 | 555х950х375 | reduced! |
A1000 series (3 phase / 400V), IP 54 * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
CIMR-AC4A0044WAA | 18,5 | 39 | 0-6000 | 275х402х197 | reduced! | |
CIMR-AC4A0058WAA | 22 | 45 | 0-6000 | 300х455х275 | reduced! | |
CIMR-AC4A0072WAA | 30 | 60 | 0-6000 | 325х505х275 | reduced! | |
CIMR-AC4A0088WAA | 37 | 75 | 0-6000 | 370х565х283 | reduced! | |
CIMR-AC4A0103WAA | 45 | 91 | 0-6000 | 370х565х283 | reduced! | |
CIMR-AC4A0139WAA | 55 | 112 | 0-6000 | 370х565х285 | reduced! | |
CIMR-AC4A0165WAA | 75 | 150 | 0-6000 | 370х565х285 | reduced! |
A1000 series (3 phase / 400V), IP 54, wall mounting * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
CIMR-AC4A0044TAA | 18,5 | 39 | 0-6000 | 400х700х260 | reduced! | |
CIMR-AC4A0058TAA | 22 | 45 | 0-6000 | 465х750х300 | reduced! | |
CIMR-AC4A0072TAA | 30 | 60 | 0-6000 | 465х750х300 | reduced! | |
CIMR-AC4A0088TAA | 37 | 75 | 0-6000 | 555х950х325 | reduced! | |
CIMR-AC4A0103TAA | 45 | 91 | 0-6000 | 555х950х325 | reduced! | |
CIMR-AC4A0139TAA | 55 | 112 | 0-6000 | 555х950х325 | reduced! | |
CIMR-AC4A0165TAA | 75 | 150 | 0-6000 | 555х950х325 | reduced! |
A1000 series (3 phase / 400V), IP 00 / NEMA1 * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
CIMR-AC4A0002FAA | 0,75 | 2.1 | 0-6000 | 140х260х147 | reduced! | |
CIMR-AC4A0004FAA | 1,5 | 4.1 | 0-6000 | 140х260х147 | reduced! | |
CIMR-AC4A0005FAA | 2,2 | 5.4 | 0-6000 | 140х260х147 | reduced! | |
CIMR-AC4A0007FAA | 3 | 6.9 | 0-6000 | 140х260х164 | reduced! | |
CIMR-AC4A0009FAA | 4 | 8.8 | 0-6000 | 140х260х164 | reduced! | |
CIMR-AC4A0011FAA | 5,5 | 11.1 | 0-6000 | 140х260х164 | reduced! | |
CIMR-AC4A0018FAA | 7,5 | 17.5 | 0-6000 | 140х260х167 | reduced! | |
CIMR-AC4A0023FAA | 11 | 23 | 0-6000 | 140х260х167 | reduced! | |
CIMR-AC4A0031FAA | 15 | 31 | 0-6000 | 180х300х167 | reduced! | |
CIMR-AC4A0038FAA | 18,5 | 38 | 0-6000 | 180х300х187 | reduced! | |
CIMR-AC4A0044FAA | 22 | 44 | 0-6000 | 220х350х197 | reduced! | |
CIMR-AC4A0058AAA | 30 | 58 | 0-6000 | 250х400х258 | reduced! | |
CIMR-AC4A0072AAA | 37 | 72 | 0-6000 | 275х450х258 | reduced! | |
CIMR-AC4A0088AAA | 45 | 88 | 0-6000 | 325х510х258 | reduced! | |
CIMR-AC4A0103AAA | 55 | 103 | 0-6000 | 325х510х258 | reduced! | |
CIMR-AC4A0139AAA | 75 | 139 | 0-6000 | 325х550х283 | reduced! | |
CIMR-AC4A0165AAA | 90 | 165 | 0-6000 | 325х550х283 | reduced! | |
CIMR-AC4A0208AAA | 110 | 208 | 0-6000 | 450х705х330 | reduced! | |
CIMR-AC4A0250AAA | 132 | 250 | 0-6000 | 500х800х350 | reduced! | |
CIMR-AC4A0296AAA | 160 | 296 | 0-6000 | 500х800х350 | reduced! | |
CIMR-AC4A0362AAA | 185 | 362 | 0-6000 | 500х800х350 | reduced! | |
CIMR-AC4A0414AAA | 220 | 414 | 0-6000 | 500х950х370 | reduced! | |
CIMR-AC4A0515AAA | 250 | 515 | 0-6000 | 670х1140х370 | reduced! | |
CIMR-AC4A0675AAA | 355 | 675 | 0-6000 | 670х1140х370 | reduced! | |
CIMR-AC4A0930AAA | 500 | 930 | 0-6000 | 1250x1380x370 | reduced! | |
CIMR-AC4A1200AAA | 630 | 1200 | 0-6000 | 1250x1380x 370 | reduced! |
Yaskawa drive A1000 series - The Most Advanced Drive Technology
- Capable of driving any kind of motor. A1000 runs not only induction motors, but also synchronous motors like IPM and SPM motors with high performance current vector control.- Minimize equipment needed for your business by using the same drive to run induction and synchronous motors.
- Switch easily between motor types with a single parameter setting.
Rotor Positioning without Motor Encoder
- Use an IPM motor to perform position control without motor feedback. Electrical saliency in IPM motors makes it possible to detect speed, direction, and rotor position without the use of a motor encoder.
- Precision positioning functionality without an upper controller. Visual programming in DriveWorksEZ lets the user easily create a customized position control sequence, without the use a motor encoder.
Powerful torque at 0 Hz, without a motor encoder* with Yaskawa frequency inverter A1000 series
Once out of reach for AC drives, Yaskawa now offers advanced control features without a motor encoder. Achieve even more powerful starting torque at zero speed with an IPM motor.
Yaskawa drive A1000 torque characteristics
Advanced Open Loop Vector Control for PM with an IPM motor.Comparing the speed control range - Advanced Open Loop Vector Control for PM with an IPM motor
High-performance current vector control for Yasawa inverter A1000 series achieves powerful starting torque with an induction motor.
Loaded with Auto-Tuning Features
- Auto-Tuning features optimize drive parameters for operation with induction motors as well as synchronous motors to achieve the highest performance levels possible.
- Perfects not only the drive and motor performance, but also automatically adjusts settings relative to the connected machinery.
A1000 continuously analyzes changes in motor characteristics during run for highly precise speed control.
Smooth Operation
Smooth low speed operation thanks to even better torque ripple suppression.Next-Generation Energy Saving
- Loaded with the most advanced energy-saving control technology*. Energy Saving control makes highly efficient operation possible with an induction motor.
* Available for models less than 450 kW.
- Amazing energy saving with a synchronous motor*. Combining the high effi ciency of a synchronous motor along with A1000ʼs Energy Saving control capabilities allows for unparalleled energy saving.
* Available for models less than 450 kW.
Environmental Features of Yaskawa frequency inverter A1000 series
- Environmental Features.
A variety of protective designs are available to reinforce the drive against moisture, dust, oil mist, vibration, corrosive sulfur gas, conductive particles, and other harsh environments.
- RoHS
All standard products are fully compliant with the EUʼs RoHS directive.
- Noise Reduction
A1000 uses Yaskawaʼs Swing PWM function* to suppress electromagnetic and audible motor noise, creating a more peaceful environment.
* Available for models less than 450 kW.
- Suppressing Power Supply Harmonics
A DC reactor minimizes harmonic distortion, standard on drives 22 kW and above.
Standard Models CIMR-A□4A0930 and 4A1200 are compatible for operation with 12-phase rectifi cation.*
* Requires a separate 3-winding transformer.
Safety Regulations for Yaskawa frequency inverter A1000 series
- The products comply with ISO/EN13849-1 Cat.3 PLd and IEC/EN61508 SIL2 (two safety inputs and one EDM output).
- An External Device Monitor (EDM) function has also been added to monitor the safety status of the drive.
- Safe Disable example: Door switch circuit. A1000 is equipped with 2 input terminals and a single output terminal for connecting a safe disable device. Input: Triggered when either terminal H1 or H2 opens. Output: EDM output monitors the safety status of the drive.