Emotron FlowDrive is designed for use in the most common pumping scenarios (1-2 pumps of any brand) in the wastewater management industry. The heart of FlowDrive is automatic reservoir level control – which optimises energy use, minimises the need for maintenance, and enables real time process monitoring. Emotron FlowDrive is designed for easy installation and is compatible with most telemetry systems. Eliminating the need for a PLC, fewer cables are needed, which means the installation is simple and cost-effective. During commissioning, the user interface prompts the customer to input the relevant operating parameters. Once up and running, performance data (for each pump, wherever separate data is of value) is continuously available.


  • Available as robust and certified IP54 metal construction or IP20/21 version
  • Fully automatic waste water reservoir level control
  • Best Efficiency Point (BEP) calculation for energy optimal operation
  • Efficiency is increased by using built-in cleaning functions; pump cleaning, sump cleaning, pipe cleaning
  • All drive sizes are delivered with built-in Category C3 EMC-filter as standard. Cat C2 as option
  • Coated board as standard
  • Temp/Speed controlled fans assures less noise, a more even drive temperature and higher efficiency
  • Detachable multi-language control panel included as standard. Following languages are supported in the control panel: English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech and Turkish
  • Removable control panel with own memory means it is easy to transfer or copy settings
  • UL/cUL (UL 840) approved version available (not IP2Y)

Additional links:

 Technical documentation and Downloads
 Request additional information and get a price quote
 

Model range

Flowdrive (3 phase 230 V) / IP54 * Discontinued series! Ask for new version or replacement!

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
FLD48-003-54 0,37 2.5 120x220x169 reduced!
FLD48-004-54 0,75 4 120x220x169 reduced!
FLD48-006-54 1,1 6 120x220x169 reduced!
FLD48-008-54 1,5 7.5 120x220x169 reduced!
FLD48-010-54 2,2 9.5 120x220x169 reduced!
FLD48-013-54 2,2 13 120x220x169 reduced!
FLD48-018-54 4 18 120x220x169 reduced!
FLD48-026-54 5,5 26 178x440x292 reduced!
FLD48-031-54 7,5 31 178x440x292 reduced!
FLD48-037-54 7,5 37 178x440x292 reduced!
FLD48-046-54 11 46 178x440x292 reduced!
FLD48-061-54 15 61 220x545x295 reduced!
FLD48-074-54 18,5 74 220x545x295 reduced!
FLD48-090-54 22 90 285x950x314 reduced!
FLD48-109-54 30 109 285x950x314 reduced!
FLD48-146-54 37 146 285x950x314 reduced!
FLD48-175-54 45 175 285x950x314 reduced!
FLD48-210-54 55 210 345x950x314 reduced!
FLD48-250-54 75 250 345x950x314 reduced!
FLD48-295-54 90 295 345x950x314 reduced!

Flowdrive (3 phase 400 V) / IP54 * Discontinued series! Ask for new version or replacement!

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
FLD48-003-54 0,75 2.5 203x350x200 reduced!
FLD48-004-54 1,5 4 203x350x200 reduced!
FLD48-006-54 2,2 6 203x350x200 reduced!
FLD48-008-54 3 7.5 203x350x200 reduced!
FLD48-010-54 4 9.5 203x350x200 reduced!
FLD48-013-54 5,5 13 203x350x200 reduced!
FLD48-018-54 7,5 18 203x350x200 reduced!
FLD48-026-54 11 26 178x440x292 reduced!
FLD48-031-54 15 31 178x440x292 reduced!
FLD48-037-54 18,5 37 178x440x292 reduced!
FLD48-046-54 22 46 178x440x292 reduced!
FLD48-061-54 30 61 220x545x295 reduced!
FLD48-074-54 37 74 220x545x295 reduced!
FLD48-090-54 45 90 285x950x314 reduced!
FLD48-109-54 55 109 285x950x314 reduced!
FLD48-146-54 75 146 285x950x314 reduced!
FLD48-175-54 90 175 285x950x314 reduced!
FLD48-210-54 110 210 345x950x314 reduced!
FLD48-250-54 132 250 345x950x314 reduced!
FLD48-295-54 160 295 345x950x314 reduced!

Flowdrive (3 phase 525 V) / IP54 * Discontinued series! Ask for new version or replacement!

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
FLD52-003-54 1,1 2.5 203x350x200 reduced!
FLD52-004-54 2,2 4 203x350x200 reduced!
FLD52-006-54 3 6 203x350x200 reduced!
FLD52-008-54 4 7.5 203x350x200 reduced!
FLD52-010-54 5,5 9.5 203x350x200 reduced!
FLD52-013-54 7,5 13 203x350x200 reduced!
FLD52-018-54 11 18 203x350x200 reduced!
FLD52-026-54 15 26 178x440x292 reduced!
FLD52-031-54 18,5 31 178x440x292 reduced!
FLD52-037-54 22 37 178x440x292 reduced!
FLD52-046-54 30 46 178x440x292 reduced!
FLD52-061-54 37 61 220x545x295 reduced!
FLD52-074-54 45 74 220x545x295 reduced!
FLD69-090 -54 55 90 345x1090x314 reduced!
FLD69-109-54 75 109 345x1090x314 reduced!
FLD69-146-54 90 146 345x1090x314 reduced!
FLD69-175-54 110 175 345x1090x314 reduced!
FLD69-200-54 132 200 345x1090x314 reduced!

Flowdrive (3 phase 230 V) / IP20 * Discontinued series! Ask for new version or replacement!

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
FLD48-2P5-2Y 0,37 2.5 120x220x169 reduced!
FLD48-3P4-2Y 0,55 3.4 120x220x169 reduced!
FLD48-4P1-2Y 0,75 4.1 120x220x169 reduced!
FLD48-5P6-2Y 1,1 5.6 120x220x169 reduced!
FLD48-7P2-2Y 1,1 7.2 120x220x169 reduced!
FLD48-9P5-2Y 2,2 9.5 120x220x169 reduced!
FLD48-012-2Y 2,2 12 120x220x169 reduced!
FLD48-016-2Y 4 16 145x255x179 reduced!
FLD48-023-2Y 5,5 23 145x255x179 reduced!
FLD48-032-2Y 7,5 31 190x335x187 reduced!
FLD48-038-2Y 11 38 190x335x187 reduced!
FLD48-025-20 5,5 25 176x446x267 reduced!
FLD48-030-20 7,5 30 176x446x267 reduced!
FLD48-036-20 7,5 36 176x446x267 reduced!
FLD48-045-20 11 45 176x446x267 reduced!
FLD48-058-20 15 58 176x446x267 reduced!
FLD48-072-20 18,5 72 220x545x291 reduced!
FLD48-088-20 22 88 220x545x291 reduced!
FLD48-105-20 30 106 220x545x291 reduced!
FLD48-142-20 37 142 275x956x294 reduced!
FLD48-171-20 45 171 275x956x294 reduced!
FLD48-205-20 55 205 335x956x294 reduced!
FLD48-244-20 75 244 335x956x294 reduced!
FLD48-293-20 90 293 335x956x294 reduced!

Flowdrive (3 phase 400 V) / IP20 * Discontinued series! Ask for new version or replacement!

Model Capacity,
kW
Current,
A
Dimensions
(W x H x D), mm
Price
FLD48-2P5-2Y 0,75 2.5 120x220x169 reduced!
FLD48-3P4-2Y 1,1 3.4 120x220x169 reduced!
FLD48-4P1-2Y 1,5 4.1 120x220x169 reduced!
FLD48-5P6-2Y 2,2 5.6 120x220x169 reduced!
FLD48-7P2-2Y 3 7.2 120x220x169 reduced!
FLD48-9P5-2Y 4 9.5 120x220x169 reduced!
FLD48-012-2Y 5,5 12 120x220x169 reduced!
FLD48-016-2Y 7,5 16 145x255x179 reduced!
FLD48-023-2Y 11 23 145x255x179 reduced!
FLD48-032-2Y 15 31 190x335x187 reduced!
FLD48-038-2Y 18,5 38 190x335x187 reduced!
FLD48-025-20 11 25 176x446x267 reduced!
FLD48-030-20 15 30 176x446x267 reduced!
FLD48-036-20 18,5 36 176x446x267 reduced!
FLD48-045-20 22 45 176x446x267 reduced!
FLD48-058-20 30 58 176x446x267 reduced!
FLD48-072-20 37 72 220x545x291 reduced!
FLD48-088-20 45 88 220x545x291 reduced!
FLD48-105-20 55 106 220x545x291 reduced!
FLD48-142-20 75 142 275x956x294 reduced!
FLD48-171-20 90 171 275x956x294 reduced!
FLD48-205-20 110 205 335x956x294 reduced!
FLD48-244-20 132 244 335x956x294 reduced!
FLD48-293-20 160 293 335x956x294 reduced!

The heart of Emotron frequency inverter FlowDrive series is automatic reservoir level control

Emotron FlowDrive is designed for use in the most common pumping scenarios (1-2 pumps of any brand) in the wastewater management industry. The heart of FlowDrive is automatic reservoir level control – which optimises energy use, minimises the need for maintenance and enables real time process monitoring.
The heart of Emotron frequency inverter FlowDrive series is automatic reservoir level control
User-friendly and reliable, Emotron FlowDrive offers the optimal price/performance ratio, backed by rapid deliveries from the factory in Sweden and local 24/7 service. Initially available in IP54 and IP20, within the 0.75-160 kW range, the new drive concept is fully tested and proven. Thanks to its coated boards in robust IP54- certified casings, you can rest assured it will withstand the challenges of demanding industrial settings.

The numerous benefits of Emotron vfd FlowDrive series

- Designed from Emotron’s long history of wellproven products for water and waste water industry
- Energy savings, thanks to automatic optimal pump speed control 
- Compatibility with all kinds of pumps typically used in this application 
- Built-in functions that minimise maintenance needs
- Absence of a PLC/pump controller reduces cost and effort involved in programming 
- Having one less component reduces complexity and increases reliability 
- Less starts and stops of the pumps thanks to longer run times caused by lower average frequency 
- Full connectivity to suit different user scenarios (remote telemetry/local control panel) 
- Complete solution packaged that is simple to install and use 
- Access to system data/parameters for continuous performance monitoring 
- Existing Emotron equipment can be upgraded to Emotron FlowDrive
The numerous benefits of Emotron vfd FlowDrive series
Self-learning system
During commissioning, the user configures all motor data and levels. The self-learning program then takes over, taking the measurements and calculating process data to enable optimal control. Features include load monitoring, best efficiency point and flow estimation.

Best efficiency point (BEP) algorithm
Initially, the drive operates in learn mode in order to establish the most efficient operating parameters for the BEP algorithm. By running the pump over a range of frequencies and measuring the volumes pumped, it defines the most energyefficient pumping frequency, and calibrates the related functions accordingly.Thereafter, the reservoir level control operates according to these defined values.
Benefits of Emotron drive FlowDrive series

All either copying or distribution of any material or information from asb-drives.eu website of Advanced Systems Baltic OÜ is forbidden unless it is allowed exclusively upon written authorization by the possessor of rights.
Bonfiglioli Inverters (VFD)
Fuji Electric Inverters (VFD)
Hitachi Inverters (VFD)
LS Inverters (VFD)
Mitsubishi Inverters (VFD)
ABB ACS580