Using new drive technology, Delta presents you with its next generation CH2000 Series AC Motor Drive. Providing high performance with robust design the CH2000 is equipped with a larger starting torque and high overload capability to fulfill the needs of heavy load and impact loading applications.
Additional links: ![]() ![]()
|
Model range

VFD-CH2000 series, voltage 200-240 V (3 phase)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
VFD007CH23A-21 | 0,75 | 5 | 0-6000 | 130x250x170 | reduced! | |
VFD015CH23A-21 | 1,5 | 8 | 0-6000 | 130x250x170 | reduced! | |
VFD022CH23A-21 | 2,2 | 11 | 0-6000 | 130x250x170 | reduced! | |
VFD037CH23A-21 | 3,7 | 17 | 0-6000 | 130x250x170 | reduced! | |
VFD055CH23A-21 | 5,5 | 25 | 0-6000 | 190x320x190 | reduced! | |
VFD075CH23A-21 | 7,5 | 33 | 0-6000 | 190x320x190 | reduced! | |
VFD110CH23A-21 | 11 | 49 | 0-6000 | 190x320x190 | reduced! | |
VFD150CH23A-21 | 15 | 65 | 0-6000 | 250x400x210 | reduced! | |
VFD185CH23A-21 | 18,5 | 75 | 0-6000 | 250x400x210 | reduced! | |
VFD220CH23A-00/-21 | 22 | 90 | 0-6000 | 330х688х275 | reduced! | |
VFD300CH23A-00/-21 | 30 | 120 | 0-6000 | 330х688х275 | reduced! | |
VFD370CH23A-00/-21 | 37 | 120 | 0-6000 | 330х688х275 | reduced! | |
VFD450CH23A-00/-21 | 45 | 180 | 0-6000 | 370x715x300 | reduced! | |
VFD550CH23A-00/-21 | 55 | 215 | 0-6000 | 370x715x300 | reduced! | |
VFD750CH23A-00/-21 | 75 | 255 | 0-6000 | 420x940x300 | reduced! |
VFD-CH2000 series, voltage 380-480 V (3 phase)
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
VFD007CH43A-21 | 0,75 | 3 | 0-6000 | 130x250x170 | reduced! | |
VFD007CH4EA-21 | 0,75 | 3 | 0-6000 | 130x250x170 | reduced! | |
VFD015CH43A-21 | 1,5 | 4 | 0-6000 | 130x250x170 | reduced! | |
VFD015CH4EA-21 | 1,5 | 4 | 0-6000 | 130x250x170 | reduced! | |
VFD022CH43A-21 | 2,2 | 6 | 0-6000 | 130x250x170 | reduced! | |
VFD022CH4EA-21 | 2,2 | 6 | 0-6000 | 130x250x170 | reduced! | |
VFD037CH43A-21 | 3,7 | 9 | 0-6000 | 130x250x170 | reduced! | |
VFD037CH4EA-21 | 3,7 | 9 | 0-6000 | 130x250x170 | reduced! | |
VFD055CH43A-21 | 5,5 | 12 | 0-6000 | 130x250x170 | reduced! | |
VFD055CH4EA-21 | 5,5 | 12 | 0-6000 | 130x250x170 | reduced! | |
VFD075CH43A-21 | 7,5 | 18 | 0-6000 | 190x320x190 | reduced! | |
VFD075CH4EA-21 | 7,5 | 18 | 0-6000 | 190x320x190 | reduced! | |
VFD110CH43A-21 | 11 | 24 | 0-6000 | 190x320x190 | reduced! | |
VFD110H4EA-21 | 11 | 24 | 0-6000 | 190x320x190 | reduced! | |
VFD150CH43A-21 | 15 | 32 | 0-6000 | 190x320x190 | reduced! | |
VFD150CH4EA-21 | 15 | 32 | 0-6000 | 190x320x190 | reduced! | |
VFD185CH43A-21 | 18,5 | 38 | 0-6000 | 250x400x210 | reduced! | |
VFD185CH4EA-21 | 18,5 | 38 | 0-6000 | 250x400x210 | reduced! | |
VFD220CH43A-21 | 22 | 45 | 0-6000 | 250x400x210 | reduced! | |
VFD220CH4EA-21 | 22 | 45 | 0-6000 | 250x400x210 | reduced! | |
VFD300CH43A-21 | 30 | 60 | 0-6000 | 250x400x210 | reduced! | |
VFD300CH4EA-21 | 30 | 60 | 0-6000 | 250x400x210 | reduced! | |
VFD0370CH43A-00/-21 | 37 | 73 | 0-6000 | 330х688х275 | reduced! | |
VFD0450CH43A-00/-21 | 45 | 91 | 0-6000 | 330х688х275 | reduced! | |
VFD0550CH43A-00/-21 | 55 | 110 | 0-6000 | 330х688х275 | reduced! | |
VFD0750CH43A-00/-21 | 75 | 150 | 0-6000 | 330х688х275 | reduced! | |
VFD0900CH43A-00/-21 | 90 | 180 | 0-6000 | 370x715x300 | reduced! | |
VFD1100CH43A-00/-21 | 110 | 220 | 0-6000 | 370x715x300 | reduced! | |
VFD1320CH43A-00/-21 | 132 | 250 | 0-6000 | 420x940x300 | reduced! | |
VFD1600CH43A-00/-21 | 160 | 310 | 0-6000 | 500x1240x397 | reduced! | |
VFD1850CH43A-00/-21 | 185 | 370 | 0-6000 | 500x1240x397 | reduced! | |
VFD2200CH43A-00/-21 | 220 | 450 | 0-6000 | 500x1240x397 | reduced! | |
VFD2800CH43A-00 | 280 | 550 | 0-6000 | 700х1435х398 | reduced! | |
VFD2800CH43C-00/-21 | 280 | 550 | 0-6000 | 700х1745х404 | reduced! |
Delta CH2000 series features
► Fast response to impact loads
► Super Heavy Duty (SHD) setting for high overload
► Large starting torque: above 200% at 0.5 Hz, and 200% at 0 Hz in FOC+PG mode
► Supports both asynchronous and synchronous motors
► Various crane functions for high operation performance
► Modular design facilitates installation process and is easy to maintain
► Built-in 10 K steps PLC programming capacity
► Built-in MODBUS communication
► Optional communication cards:
Advanced Crane Function for Delta AC motor drive CH2000 series
►Mechanical brake control 8 independent brake control setting to different criteria. High flexibility to meet complex application needs and ensure operation safety.
►Advanced crane time sequence Brake delay and dwell function ensure smooth operation.
Auto-acceleration of Light Load
Delta plc CH2000 series has an excellent overload capability
The super heavy duty setting is suitable for harsh environment applications with a current overload capability of 150% for 60 seconds and 200% for 3 seconds.
Standard Models
► Power Range 3-phase 230V series: 0.75 ~ 75kW (1hp~100hp) 3-phase 460V series: 0.75 ~ 280kW (1hp~375hp)