Rockwell Automation frequency inverters PowerFlex 400 fan and pump series

Rockwell Automation
 


PowerFlex® 400 AC Drives are optimized for control of commercial and industrial fans and pumps. Built-in features such as purge and damper input provide a cost-effective solution for speed control in a broad range of variable torque fan and pump applications. An available packaged PowerFlex 400 Fan and Pump drive provides additional control, power, and enclosure options in standardized designs for a cost-effective solution for speed control in variable torque fan and pump applications.


  • NEMA/UL Type 1, 12, 3R, and 4 enclosures
  • Flange-mount and panel-mount options
  • V/Hz control, slip compensation, and PID control
  • Internal RS-485, Common Industrial Protocol (CIP), embedded Modbus® RTU, Metasys® N2, and Apogee® FLN P1-plant floor network protocols
  • Supports Drive Serial Interface (DSI) communication modules
  • Drive overload protection, flying start, purge and damper input, hand/off/auto, and sleep/wake features
  • Packaged drive options include disconnect and contactor bypass packages
  • Available line reactor option
  • Configuration and programming via integral keypad, remote keypad, or DriveTools™ SP software
  • Premier Integration with PowerFlex® AC drives uses the Logix control platform to simplify parameter and tag programming and reduces development time


Additional links:

 Technical documentation and Downloads
 Request additional information and get a price quote

 

Model range

PowerFlex 400 (3 phase 200-240 V)

Model Capacity,
kW
Current,
A
Deceleration time, sec Dimensions
(W x H x D), mm
Price
22C-B012N103 2,2 12 0-600 130x260x180 reduced!
22C-B017N103 3,7 17.5 0-600 130x260x180 reduced!
22C-B024N103 5,5 24 0-600 130x260x180 reduced!
22C-B033N103 7,5 33 0-600 130x260x180 reduced!
22C-B049A103 11 49 0-600 250x436,2x206,1 reduced!
22C-B065A103 15 65 0-600 250x436,2x206,1 reduced!
22C-B075A103 18,5 75 0-600 250x436,2x206,1 reduced!
22C-B090A103 22 90 0-600 250x436,2x206,1 reduced!
22C-B120A103 30 120 0-600 370x605,5x259,2 reduced!
22C-B145A103 37 145 0-600 370x605,5x259,2 reduced!

PowerFlex 400 (3 phase 380-480 V)

Model Capacity,
kW
Current,
A
Deceleration time, sec Dimensions
(W x H x D), mm
Price
22C-D6P0N103 2,2 6 0-600 130x260x180 reduced!
22C-D010N103 4 10.5 0-600 130x260x180 reduced!
22C-D012N103 5,5 12 0-600 130x260x180 reduced!
22C-D017N103 7,5 17 0-600 130x260x180 reduced!
22C-D022N103 11 22 0-600 130x260x180 reduced!
22C-D030N103 15 30 0-600 130x260x180 reduced!
22C-D038A103 18,5 38 0-600 250x436,2x206,1 reduced!
22C-D045A103 22 45.5 0-600 250x436,2x206,1 reduced!
22C-D060A103 30 60 0-600 250x436,2x206,1 reduced!
22C-D072A103 37 72 0-600 370x605,5x259,2 reduced!
22C-D088A103 45 88 0-600 370x605,5x259,2 reduced!
22C-D105A103 55 75 0-600 370x605,5x259,2 reduced!
22C-D142A103 75 142 0-600 370x605,5x259,2 reduced!
22C-D170A103 90 170 0-600 425x678x264 reduced!
22C-D208A103 110 208 0-600 425x678x264 reduced!
22C-D260A103 132 260 0-600 425x892x264 reduced!
22C-D310A103 160 310 0-600 425x892x264 reduced!
22C-D370A103 200 370 0-600 529,2x1363,8x358,6 reduced!
22C-D460A103 250 460 0-600 529,2x1363,8x358,6 reduced!

Rockwell Powerflex drive 400 series is Optimized for Commercial Fan and Pump Applications

Providing users with easy installation and ideal for mechanical fan and pump systems, the PowerFlex 400 AC drive offers a wide range of built-in features that allow for seamless building system integration. The PowerFlex 400 is designed to meet global OEM, contractor and end-user demands for flexibility, space savings and ease-of-use.
- Power ratings of 2.2...250 kW/3.0...350 Hp at 380-480V and 2.2...37 kW/3.0...50 Hp at 200-240V 
- Integral PID controller allows a process variable to be maintained by automatically adjusting the output frequency 
- Three programmable skip frequencies and bands prevent the drive from running continuously at resonant speeds, which could cause mechanical breakdowns 
- Selectable fan/pump curves provide reduced voltage patterns for centrifugal fan and pump loads 
- Sleep function allows the drive to be cycled off when the system demand drops below a preset level and to be restarted automatically when the demand increases 
- For applications that require unattended operation, the Start at Power Up function provides the ability to resume running after power is restored due to a power outage 
- Connection to fire and life safety systems via freeze/fire and purge inputs 
- Auxiliary motor control allows staging of additional line-started motors to meet system demand 
- Damper input can be used to disable the drive output until desired damper position is obtained, even with a valid run command

When your application requires a compact drive optimized for fans or pumps, take advantage of a cost effective solution with application specific features. PowerFlex 400 AC drives offer ease of configuration, low-cost networking and flexible installation.

Rockwell Powerflex vfd 400 series Communications 

- RS485 communications integral to base drive 
- Embedded Modbus RTU, Metasys N2 and P1-Plant Floor Network protocols are parameter selectable and require no additional hardware or software 
- Supports Drive Serial Interface (DSI) communication modules and accessories including DeviceNet™, EtherNet/IP™, ControlNet™, PROFIBUS™ DP, BACnet®, LonWorks® and Bluetooth® communications adapters

Configuration

There are several ways to quickly and easily configure PowerFlex 400 AC drives. From the integral LED HIM, to Connected Components Workbench™ software or the Studio 5000 Logix Designer® application, these tools are designed to help you reduce development time so you can deliver machines faster and more efficiently. 

Rockwell Powerflex frequency inverter 400 series packaging

- Disconnect and contactor bypass packages in NEMA 1, 12, 3R and 4 designs simplify installation and startup by combining operator interface, control, communications and power options in preconfigured assemblie
- Contactor bypass packages supplied with three contactors allowing drive test functionality and drive isolation when in bypass mode
- Meets seismic requirements of the 2003 International Building Code as specified by AC156

Rockwell PowerFlex 400 AC Drive at a glance

Providing users with easy installation and ideal for mechanical fan and pump systems, the PowerFlex 400 AC drive offers a wide range of built-in features that allow for seamless building system integration. The PowerFlex 400 is designed to meet global OEM, contractor and end-user demands for flexibility, space savings, and ease-of-use.

Rockwell PowerFlex vfd 400 AC series at a glance
All either copying or distribution of any material or information from asb-drives.eu website of Advanced Systems Baltic OÜ is forbidden unless it is allowed exclusively upon written authorization by the possessor of rights.
Bonfiglioli Inverters (VFD)
Fuji Electric Inverters (VFD)
Hitachi Inverters (VFD)
LS Inverters (VFD)
Mitsubishi Inverters (VFD)
ABB ACS580
ABB ACS880