The Altivar 61 drive is a frequency inverter for three-phase synchronous and asynchronous motors. It has been designed for common fluid management applications in industrial and commercial buildings and infrastructures. The Altivar 61 can increase the performance of equipment and reduce operating costs in buildings by optimizing energy consumption whilst improving user comfort. The Altivar 61 drive has been developed to meet the requirements of directives regarding the protection of the environment (RoHS, REACH, WEEE, etc.) as well as those of European Directives to obtain the e mark.
Additional links: ![]() ![]() |
Model range

Altivar 61 series, voltage 200-240 V (1 phase) * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
ATV 61H075M3 | 0,37 | 3 | 0,1-999,9 | 130х230х175 | reduced! | |
ATV 61HU15M3 | 0,75 | 4.8 | 0,1-999,9 | 130х230х175 | reduced! | |
ATV 61HU22M3 | 1,5 | 8 | 0,1-999,9 | 155х260х187 | reduced! | |
ATV 61HU30M3 | 2,2 | 11 | 0,1-999,9 | 155х260х187 | reduced! | |
ATV 61HU40M3 | 3 | 13.7 | 0,1-999,9 | 155х260х187 | reduced! | |
ATV 61HU55M3 | 4 | 17.5 | 0,1-999,9 | 175х295х187 | reduced! | |
ATV 61HU75M3 | 5,5 | 27.5 | 0,1-999,9 | 210х295х213 | reduced! |
Altivar 61 series, voltage 200-240 V (3 phase) * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
ATV 61H075M3 | 0,75 | 4.8 | 0,1-999,9 | 130х230х175 | reduced! | |
ATV 61HU15M3 | 1,5 | 8 | 0,1-999,9 | 130х230х175 | reduced! | |
ATV 61HU22M3 | 2,2 | 11 | 0,1-999,9 | 155х260х187 | reduced! | |
ATV 61HU30M3 | 3 | 13.7 | 0,1-999,9 | 155х260х187 | reduced! | |
ATV 61HU40M3 | 4 | 17.5 | 0,1-999,9 | 155х260х187 | reduced! | |
ATV 61HU55M3 | 5,5 | 27.5 | 0,1-999,9 | 175х295х187 | reduced! | |
ATV 61HU75M3 | 7,5 | 33 | 0,1-999,9 | 210х295х213 | reduced! | |
ATV 61HD11M3X | 11 | 54 | 0,1-999,9 | 230х400х213 | reduced! | |
ATV 61HD15M3X | 15 | 66 | 0,1-999,9 | 230х400х213 | reduced! | |
ATV 61HD18M3X | 18,5 | 75 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HD22M3X | 22 | 88 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HD30M3X | 30 | 120 | 0,1-999,9 | 320х550х266 | reduced! | |
ATV 61HD37M3X | 37 | 144 | 0,1-999,9 | 320х550х266 | reduced! | |
ATV 61HD45M3X | 45 | 176 | 0,1-999,9 | 320х550х266 | reduced! | |
ATV 61HD55M3X | 55 | 221 | 0,1-999,9 | 320x650x377 | reduced! | |
ATV 61HD75M3X | 75 | 285 | 0,1-999,9 | 320x650x377 | reduced! | |
ATV 61HD90M3X | 90 | 359 | 0,1-999,9 | 360x1022х377 | reduced! |
Altivar 61 series, voltage 380-480 V (3 phase), IP20 protection * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
ATV 61H075N4 | 0,75 | 2.3 | 0,1-999,9 | 130х230х175 | reduced! | |
ATV 61HU15N4 | 1,5 | 5 | 0,1-999,9 | 130х230х175 | reduced! | |
ATV 61HU22N4 | 2,2 | 5.8 | 0,1-999,9 | 130х230х175 | reduced! | |
ATV 61HU30N4 | 3 | 7.8 | 0,1-999,9 | 155х260х187 | reduced! | |
ATV 61HU40N4 | 4 | 10.5 | 0,1-999,9 | 155х260х187 | reduced! | |
ATV 61HU55N4 | 5,5 | 14.3 | 0,1-999,9 | 175х295х187 | reduced! | |
ATV 61HU75N4 | 7,5 | 17.6 | 0,1-999,9 | 175х295х187 | reduced! | |
ATV 61HD11N4 | 11 | 27.7 | 0,1-999,9 | 210х295х213 | reduced! | |
ATV 61HD15N4 | 15 | 33 | 0,1-999,9 | 230х400х213 | reduced! | |
ATV 61HD18N4 | 18,5 | 41 | 0,1-999,9 | 230х400х213 | reduced! | |
ATV 61HD22N4 | 22 | 48 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HD30N4 | 30 | 66 | 0,1-999,9 | 240х550х266 | reduced! | |
ATV 61HD37N4 | 37 | 79 | 0,1-999,9 | 240х550х266 | reduced! | |
ATV 61HD45N4 | 45 | 94 | 0,1-999,9 | 320х630х290 | reduced! | |
ATV 61HD55N4 | 55 | 116 | 0,1-999,9 | 320х630х290 | reduced! | |
ATV 61HD75N4 | 75 | 160 | 0,1-999,9 | 320х630х290 | reduced! | |
ATV 61HD90N4 | 90 | 179 | 0,1-999,9 | 320х920х377 | reduced! | |
ATV 61HC11N4 | 110 | 215 | 0,1-999,9 | 320х920х377 | reduced! | |
ATV 61HC13N4 | 132 | 259 | 0,1-999,9 | 360х1022х377 | reduced! | |
ATV 61HC16N4 | 160 | 314 | 0,1-999,9 | 340х1190х377 | reduced! | |
ATV 61HC22N4 | 200 | 427 | 0,1-999,9 | 440х1190х377 | reduced! | |
ATV 61HC25N4 | 250 | 481 | 0,1-999,9 | 595х1190х377 | reduced! | |
ATV 61HC31N4 | 280 | 616 | 0,1-999,9 | 595х1190х377 | reduced! | |
ATV 61HC40N4 | 355 | 759 | 0,1-999,9 | 890х1390х377 | reduced! | |
ATV 61HC50N4 | 500 | 941 | 0,1-999,9 | 890х1390х377 | reduced! | |
ATV 61HC63N4 | 560 | 1188 | 0,1-999,9 | 1120х1390х377 | reduced! |
Altivar 61 series, voltage 380-480 V (3 phase), IP 54, with integrated EMC filter class A or B * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
ATV 61W075N4(С) | 0,75 | 2.3 | 0,1-999,9 | 240х490х272 | reduced! | |
ATV 61WU15N4(С) | 1,5 | 5 | 0,1-999,9 | 240х490х272 | reduced! | |
ATV 61WU22N4(C) | 2,2 | 5.1 | 0,1-999,9 | 240х490х272 | reduced! | |
ATV 61WU30N4(C) | 3 | 7.2 | 0,1-999,9 | 240х490х272 | reduced! | |
ATV 61WU40N4(C) | 4 | 9.1 | 0,1-999,9 | 240х490х286 | reduced! | |
ATV 61WU55N4(C) | 5,5 | 12 | 0,1-999,9 | 240х490х286 | reduced! | |
ATV 61WU75N4(C) | 7,5 | 16 | 0,1-999,9 | 260х525х286 | reduced! | |
ATV 61WD11N4(C) | 11 | 22.5 | 0,1-999,9 | 260х525х286 | reduced! | |
ATV 61WD15N4(C) | 15 | 30.5 | 0,1-999,9 | 295х560х315 | reduced! | |
ATV 61WD18N4(C) | 18,5 | 37 | 0,1-999,9 | 315х665х315 | reduced! | |
ATV 61WD22N4(C) | 22 | 43.5 | 0,1-999,9 | 315х665х315 | reduced! | |
ATV 61WD30N4(C) | 30 | 58.5 | 0,1-999,9 | 285х720х315 | reduced! | |
ATV 61WD37N4(C) | 37 | 71.5 | 0,1-999,9 | 285х880х343 | reduced! | |
ATV 61WD45N4(C) | 45 | 85 | 0,1-999,9 | 285х880х343 | reduced! | |
ATV 61WD55N4(C) | 55 | 103 | 0,1-999,9 | 362х1000х364 | reduced! | |
ATV 61WD75N4(C) | 75 | 137 | 0,1-999,9 | 362х1000х364 | reduced! | |
ATV 61WD90N4(C) | 90 | 163 | 0,1-999,9 | 362х1000х364 | reduced! |
Altivar 61 series, voltage 500-690 V (3 phase) * Discontinued series! Ask for new version or replacement!
Model | Capacity, kW |
Current, A |
Deceleration time, sec | Dimensions (W x H x D), mm |
Price | |
---|---|---|---|---|---|---|
ATV 61HU30Y | 3 | 4.5 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HU40Y | 4 | 5.5 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HU55Y | 5,5 | 7.5 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HU75Y | 7,5 | 10 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HD11Y | 11 | 13.5 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HD15Y | 15 | 18.5 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HD18Y | 18,5 | 24 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HD22Y | 22 | 27 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HD30Y | 30 | 35 | 0,1-999,9 | 240х420х236 | reduced! | |
ATV 61HD37Y | 37 | 43 | 0,1-999,9 | 320х630х290 | reduced! | |
ATV 61HD45Y | 45 | 54 | 0,1-999,9 | 320х630х290 | reduced! | |
ATV 61HD55Y | 55 | 62 | 0,1-999,9 | 320х630х290 | reduced! | |
ATV 61HD75Y | 75 | 84 | 0,1-999,9 | 320х630х290 | reduced! | |
ATV 61HD90Y | 90 | 104 | 0,1-999,9 | 320х630х290 | reduced! | |
ATV 61HC11Y | 110 | 125 | 0,1-999,9 | 340х1190х377 | reduced! | |
ATV 61HC13Y | 132 | 150 | 0,1-999,9 | 340х1190х377 | reduced! | |
ATV 61HC16Y | 160 | 180 | 0,1-999,9 | 340х1190х377 | reduced! | |
ATV 61HC20Y | 200 | 220 | 0,1-999,9 | 340х1190х377 | reduced! | |
ATV 61HC25Y | 250 | 290 | 0,1-999,9 | 595х1190х377 | reduced! | |
ATV 61HC31Y | 315 | 355 | 0,1-999,9 | 595х1190х377 | reduced! | |
ATV 61HC40Y | 400 | 420 | 0,1-999,9 | 595х1190х377 | reduced! | |
ATV 61HC50Y | 500 | 543 | 0,1-999,9 | 1120х1390х377 | reduced! | |
ATV 61HC63Y | 630 | 675 | 0,1-999,9 | 1120х1390х377 | reduced! | |
ATV 61HC80Y | 800 | 840 | 0,1-999,9 | 1120х1390х377 | reduced! |
Schneider Electric frequency inverter Altivar 61 series is environmentally-friendly and energy-saving
The drive is designed to be environmentally-friendly:
- Energy saving with a reduction in energy consumption of 70 % for ventilation applications and 50 % for pumping applications
- Reduction of fluid losses in distribution networks
- Use of 80 % recyclable materials - the Altivar 61 drive conforms to environmental standard ISO 14040 which defines a critical analysis of the product's impact on the environment
Compliance with international standards and certifications
The Altivar 61 drive has been developed to meet the requirements of directives regarding the protection of the environment (RoHS, REACH, WEEE, etc.) as well as those of European Directives to obtain the e mark. The entire range is UL, CSA, DNV, C-Tick, NOM and GOST certified and conforms to international standards relating to electrical industrial control equipment IEC/EN 61800-2 and IEC/EN 61800-5-1. The need for electromagnetic compatibility was taken into account at the outset when designing the drive. The entire range conforms to international standard IEC/EN 61800-3. The Altivar 61 drive complies with the requirements of safety standards for applications in explosive atmospheres (ATEX)
An extensive range
The Altivar 61 range offers numerous variants to meet the requirements of applications in a wide variety of fields and in very harsh environments. With these variants, the Altivar 61 range offers ready-to-use or modular solutions that can adapt to your needs.
Its numerous and comprehensive options enable it to be adapted and incorporated into electrical installations, sophisticated control systems, infrastructures and building management systems. They also create significant energy savings and reduce line interference.
A specific option, the Active Front End, enables the Altivar 61 to be used in installations where particularly low harmonic levels are required. It also allows the Altivar 61 drive to operate on unstable line supplies.
Schneider Electric vfd Altivar 61 series for pumps has a wide range of applications
The Altivar 61 drive incorporates advanced functions for optimum efficiency in the majority of applications in the industrial or commercial buildings sector:
- Ventilation
- Air conditioning
- Air purification, smoke extraction
- Fluid management
- Pumping and booster stations
- Irrigation stations
- Off-shore drilling rigs
Advanced functions
The Altivar 61 drive meets stringent requirements due to its numerous integrated application functions, while helping ensure the reliability of equipment with its protection and safety functions.
Functions designed specifically for pump and fan applications
- Energy saving ratio, 2 or 5 point quadratic ratio
- Automatic catching a spinning load with speed detection
- Adaptation of current limiting according to speed
- Noise and resonance suppression due to the possibility of adjusting the switching frequency during operation up to 16 kHz depending on the rating and the possibility of making frequency skips
- Preset speeds b Integrated PID regulator with preset PID references and automatic/manual (Auto/Man.) mode
- Electricity and service hours meter
- Fluid absence detection, zero flow and limited flow detection
- Sleep function, wake-up function
- Customer settings with display of physical measurements (bar, I/s, °C, etc.)
Protection functions
- Motor and drive thermal protection, PTC thermal probe management
- Protection against overloads and overcurrents in continuous operation
- Machine mechanical protection via skip frequency function, output phase rotation
- Protection of the installation by means of underload, overload and zero flow detection
- Protection via management of multiple faults and configurable alarms
Safety functions
- Machine safety via the integrated Power Removal function This function stops the motor and helps preventing accidental restarts; it complies with machine safety standard ISO 1389-1, category 3 and the standard for functional safety IEC/EN 61508, SIL2 capability (safety control-signalling applied to processes and systems). This safety function means that the drive can be installed as part of the safety system for an Electrical/Electronic/Programmable Electronic control system relating to the safety of a machine or industrial process.
- Means of the forced operation function with configurable fault inhibiting, direction of operation and references help ensure installation safety.